Mass transfer examination in electrodialysis using limiting current measurements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F28676092%3A_____%2F14%3A%230000370" target="_blank" >RIV/28676092:_____/14:#0000370 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mass transfer examination in electrodialysis using limiting current measurements
Popis výsledku v původním jazyce
The impact of electrodialysis module characteristics on mass transfer was examined using the limiting current method. The current-voltage curves of different electrodialysis modules were measured and limiting currents were determined using the derivativemethod. The mass transfer coefficients were calculated and the parameters of their dependence on linear flow velocity were estimated. From these the impact of spacer thickness, spacer net type, membrane type, and module geometry were evaluated. It was found that the impact of spacer thickness was almost negligible within the examined range, but a decrease in the mass transfer coefficient could be expected in the case of thicker spacers. By contrast, the spacer net type and type of membrane were found to be very important parameters able to significantly influence the mass transfer. By modifying the module geometry, the mass transfer coefficient could also be altered and, only in this case, the exponential parameter of the dependence wa
Název v anglickém jazyce
Mass transfer examination in electrodialysis using limiting current measurements
Popis výsledku anglicky
The impact of electrodialysis module characteristics on mass transfer was examined using the limiting current method. The current-voltage curves of different electrodialysis modules were measured and limiting currents were determined using the derivativemethod. The mass transfer coefficients were calculated and the parameters of their dependence on linear flow velocity were estimated. From these the impact of spacer thickness, spacer net type, membrane type, and module geometry were evaluated. It was found that the impact of spacer thickness was almost negligible within the examined range, but a decrease in the mass transfer coefficient could be expected in the case of thicker spacers. By contrast, the spacer net type and type of membrane were found to be very important parameters able to significantly influence the mass transfer. By modifying the module geometry, the mass transfer coefficient could also be altered and, only in this case, the exponential parameter of the dependence wa
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JP - Průmyslové procesy a zpracování
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0084" target="_blank" >ED2.1.00/03.0084: Membránové inovační centrum</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Údaje specifické pro druh výsledku
Název periodika
Chemical Papers
ISSN
1336-9075
e-ISSN
—
Svazek periodika
69 (4)
Číslo periodika v rámci svazku
69 (4)
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
7
Strana od-do
7
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—