Analysis of the impact of errors in electrodialyzers assembling on their functionality
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F28676092%3A_____%2F15%3A%230000480" target="_blank" >RIV/28676092:_____/15:#0000480 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of the impact of errors in electrodialyzers assembling on their functionality
Popis výsledku v původním jazyce
The purpose of this work includes the assessment of the impact of five (5) different types of assembly errors on the performance of electrodialysis stacks during standard electrodialysis operation and electrodialysis reversal. Studies were conducted withsodium sulfate solutions in batch mode. Performance of stack configurations was evaluated by measuring salt removal against current efficiency and energy consumption to obtain one kg salt or one liter of desalted water. The process was performed by applying a voltage of 10 V until a final diluate conductivity of less than 1 mS cm-1 was achieved. For all 5 error types, the duration of electrochemical tests exceeded the standard 55 ? 60 minutes. With respect to efficiencies, the current efficiency of stacks with errors was 14.5% lower than the standard 90% while the energy consumption was 19.8% higher on average. On the basis of these results, efficient troubleshooting may be performed during the electrochemical quality control step of t
Název v anglickém jazyce
Analysis of the impact of errors in electrodialyzers assembling on their functionality
Popis výsledku anglicky
The purpose of this work includes the assessment of the impact of five (5) different types of assembly errors on the performance of electrodialysis stacks during standard electrodialysis operation and electrodialysis reversal. Studies were conducted withsodium sulfate solutions in batch mode. Performance of stack configurations was evaluated by measuring salt removal against current efficiency and energy consumption to obtain one kg salt or one liter of desalted water. The process was performed by applying a voltage of 10 V until a final diluate conductivity of less than 1 mS cm-1 was achieved. For all 5 error types, the duration of electrochemical tests exceeded the standard 55 ? 60 minutes. With respect to efficiencies, the current efficiency of stacks with errors was 14.5% lower than the standard 90% while the energy consumption was 19.8% higher on average. On the basis of these results, efficient troubleshooting may be performed during the electrochemical quality control step of t
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JP - Průmyslové procesy a zpracování
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1418" target="_blank" >LO1418: Progresivní rozvoj Membránového inovačního centra</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Údaje specifické pro druh výsledku
Název statě ve sborníku
Workshop od Students´ Presentations 2015 "Membranes and Membrane Processes"
ISBN
978-80-904517-4-2
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
9
Název nakladatele
Česká membránová platforma
Místo vydání
Česká Lípa
Místo konání akce
Stráž pod Ralskem
Datum konání akce
21. 10. 2015
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—