Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F28778758%3A_____%2F17%3AN0000014" target="_blank" >RIV/28778758:_____/17:N0000014 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43210/17:43911855 RIV/62156489:43410/17:43911855 RIV/00216275:25310/17:39912237 RIV/00216305:26220/17:PU124749 RIV/00216224:14310/17:00120390
Výsledek na webu
<a href="http://www.mdpi.com/1424-8220/17/8/1832" target="_blank" >http://www.mdpi.com/1424-8220/17/8/1832</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s17081832" target="_blank" >10.3390/s17081832</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide
Popis výsledku v původním jazyce
In this study, the preparation and electrochemical application of a chromium(III) oxide modified carbon paste electrode (Cr-CPE) and a screen printed electrode (SPE), made from the same material and optimized for the simple, cheap and sensitive simultaneous determination of zinc, cadmium, lead, copper and the detection of silver ions, is described. The limits of detection and quantification were 25 and 80 micrograms/L for Zn(II), 3 and 10 micrograms/L for Cd(II), Pb(II), Cu(II) and Ag(I), respectively. Furthermore, this promising modification was transferred to the screen-printed electrode. The limits of detection for the simultaneous determination of zinc, cadmium, copper and lead on the screen printed electrodes were found to be 350 micrograms/L for Zn(II), 25 micrograms/L for Cd(II), 3 micrograms/L for Pb(II) and Cu(II). Practical usability for the simultaneous detection of these heavy metal ions by the Cr-CPE was also demonstrated in the analyses of wastewaters.
Název v anglickém jazyce
Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide
Popis výsledku anglicky
In this study, the preparation and electrochemical application of a chromium(III) oxide modified carbon paste electrode (Cr-CPE) and a screen printed electrode (SPE), made from the same material and optimized for the simple, cheap and sensitive simultaneous determination of zinc, cadmium, lead, copper and the detection of silver ions, is described. The limits of detection and quantification were 25 and 80 micrograms/L for Zn(II), 3 and 10 micrograms/L for Cd(II), Pb(II), Cu(II) and Ag(I), respectively. Furthermore, this promising modification was transferred to the screen-printed electrode. The limits of detection for the simultaneous determination of zinc, cadmium, copper and lead on the screen printed electrodes were found to be 350 micrograms/L for Zn(II), 25 micrograms/L for Cd(II), 3 micrograms/L for Pb(II) and Cu(II). Practical usability for the simultaneous detection of these heavy metal ions by the Cr-CPE was also demonstrated in the analyses of wastewaters.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors
ISSN
1424-8220
e-ISSN
1424-8220
Svazek periodika
17
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
14
Strana od-do
1832/1-1832/14
Kód UT WoS článku
000408576900135
EID výsledku v databázi Scopus
2-s2.0-85027274640