Arctic Air Cooler
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13420%2F15%3A43886994" target="_blank" >RIV/44555601:13420/15:43886994 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Arctic Air Cooler
Popis výsledku v původním jazyce
This article deals with the design of a process recirculation air cooler for cooling natural gas when the latter is processed. The cooler is intended for extreme climatic conditions, and due to this reason, it is necessary when designing and fabricatingthe cooler to comply with the specific requirements for both the calculation and materials to be used on constructing it. In the winter period when the ambient temperature drops even below the solidification point of the medium the cooler works with reduced rpm of the fan, and when necessary, even in the recirculation mode, partial or full (depending on the ambient temperature). In this case, the inlet and outlet louvers are closed, and the recirculation louvers are opened. This system allows, using thecontrol of the temperature of the inlet cooling air, to maintain the temperature of the cooled medium at the desired level.
Název v anglickém jazyce
Arctic Air Cooler
Popis výsledku anglicky
This article deals with the design of a process recirculation air cooler for cooling natural gas when the latter is processed. The cooler is intended for extreme climatic conditions, and due to this reason, it is necessary when designing and fabricatingthe cooler to comply with the specific requirements for both the calculation and materials to be used on constructing it. In the winter period when the ambient temperature drops even below the solidification point of the medium the cooler works with reduced rpm of the fan, and when necessary, even in the recirculation mode, partial or full (depending on the ambient temperature). In this case, the inlet and outlet louvers are closed, and the recirculation louvers are opened. This system allows, using thecontrol of the temperature of the inlet cooling air, to maintain the temperature of the cooled medium at the desired level.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Manufacturing Technology
ISSN
1213-2489
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
920-924