Characteristic signal of FT3 measuring probe
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13420%2F19%3A43894974" target="_blank" >RIV/44555601:13420/19:43894974 - isvavai.cz</a>
Výsledek na webu
<a href="https://arl.ujep.cz/arl-ujep/en/csg/?repo=ujeprepo&key=48136628730" target="_blank" >https://arl.ujep.cz/arl-ujep/en/csg/?repo=ujeprepo&key=48136628730</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21062/ujep/263.2019/a/1213-2489/mt/19/1/168" target="_blank" >10.21062/ujep/263.2019/a/1213-2489/mt/19/1/168</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Characteristic signal of FT3 measuring probe
Popis výsledku v původním jazyce
The article deals with the determining of the characteristic signal of the inductive FT3 measuring probe, that is used on the roundness machines of Jenoptik IM producer. The research was the basis for generalized recommendations for the calibration of the probe, which was published in the article "A roundness machine measuring probe calibration". The signals of eight FT3 probes have been acquired and evaluated for repeatability and mutual equality. Five signals of each individual probe were taken immediately for repeatability evaluation. The deviations of the individual signals from the mean signal and the deviations of the signal first derivative curves from the mean first derivative curve have been evaluated for the repeatability evaluation. The deviations of the signal of the individual probes from the perfect signal have been evaluated for the equality evaluation.
Název v anglickém jazyce
Characteristic signal of FT3 measuring probe
Popis výsledku anglicky
The article deals with the determining of the characteristic signal of the inductive FT3 measuring probe, that is used on the roundness machines of Jenoptik IM producer. The research was the basis for generalized recommendations for the calibration of the probe, which was published in the article "A roundness machine measuring probe calibration". The signals of eight FT3 probes have been acquired and evaluated for repeatability and mutual equality. Five signals of each individual probe were taken immediately for repeatability evaluation. The deviations of the individual signals from the mean signal and the deviations of the signal first derivative curves from the mean first derivative curve have been evaluated for the repeatability evaluation. The deviations of the signal of the individual probes from the perfect signal have been evaluated for the equality evaluation.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Manufacturing Technology
ISSN
1213-2489
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
168-171
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85063348799