Orientovaná a vratná imobilizace přirozeného a rekombinantního fotosystému II na povrchu zlatých elektrod
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13430%2F04%3A00002604" target="_blank" >RIV/44555601:13430/04:00002604 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388971:_____/04:00022289
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Monolayers of natural and recombinant photosystem II on gold electrodes - potentials for use as biosensors for detection of herbicides
Popis výsledku v původním jazyce
Two methods for monolayer immobilisation of photosystem II isolated from thermophilic cyanobacteria Synechococcus elongatus and prospects for its use as a biosensor for detection of herbicides are reported: (i) Immobilisation based on recombinant (His)6-tagged PSII coupled with Ni-NTA chelator monolayer on Au electrode. (ii) Immobilisation based on the natural PSII coupled with the protein A - anti-D1 antibody modified Au electrode. Here, CYS-SAM-NTA-PSII monolayers were compared with traditional BSA-GA-PSII cross-linked gel matrix and better performances of the derived electrochemical biosensors were pointed out. Better diffusion of inhibitors and mediators resulted in improved sensitivity, velocity of the response and lower I50 for herbicides.
Název v anglickém jazyce
Monolayers of natural and recombinant photosystem II on gold electrodes - potentials for use as biosensors for detection of herbicides
Popis výsledku anglicky
Two methods for monolayer immobilisation of photosystem II isolated from thermophilic cyanobacteria Synechococcus elongatus and prospects for its use as a biosensor for detection of herbicides are reported: (i) Immobilisation based on recombinant (His)6-tagged PSII coupled with Ni-NTA chelator monolayer on Au electrode. (ii) Immobilisation based on the natural PSII coupled with the protein A - anti-D1 antibody modified Au electrode. Here, CYS-SAM-NTA-PSII monolayers were compared with traditional BSA-GA-PSII cross-linked gel matrix and better performances of the derived electrochemical biosensors were pointed out. Better diffusion of inhibitors and mediators resulted in improved sensitivity, velocity of the response and lower I50 for herbicides.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA522%2F03%2F0659" target="_blank" >GA522/03/0659: Zdokonalení fotosyntetického biosenzoru a biologických testů pro rutinní detekci reziduí herbicidů a určení rizik pro necílové organismy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Letters
ISSN
0003-2719
e-ISSN
—
Svazek periodika
37
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
1-12
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—