The Effects of Pole Length on the Energy Output in Nordic Walking
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13430%2F11%3A43883297" target="_blank" >RIV/44555601:13430/11:43883297 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Effects of Pole Length on the Energy Output in Nordic Walking
Popis výsledku v původním jazyce
This study investigates the influence of different lengths of sticks on individual energy expenditure in Nordic walking. The various sources dealing with this subject is given different coefficients for length settings poles, which are quite different. We thought that this difference in the length of a stick, could have a significant impact not only on the actual energy expenditure of an individual, but also on other parameters measured. Tested were 9 purposely selected probands who had been with the movement already experienced. The actual testing was carried out in laboratory conditions on a treadmill, which were recorded during testing, the value of heart rate (HR), maximum heart rate (HRmax), maximal lung ventilation (VE), breathing frequency (BF)and the main indicator of energy expenditure VO2. VO2 values ??were then converted to calories, as indicators of energy intensity. Based on the Wilcoxon test, we investigated whether or not, these values ??between the measurements of the
Název v anglickém jazyce
The Effects of Pole Length on the Energy Output in Nordic Walking
Popis výsledku anglicky
This study investigates the influence of different lengths of sticks on individual energy expenditure in Nordic walking. The various sources dealing with this subject is given different coefficients for length settings poles, which are quite different. We thought that this difference in the length of a stick, could have a significant impact not only on the actual energy expenditure of an individual, but also on other parameters measured. Tested were 9 purposely selected probands who had been with the movement already experienced. The actual testing was carried out in laboratory conditions on a treadmill, which were recorded during testing, the value of heart rate (HR), maximum heart rate (HRmax), maximal lung ventilation (VE), breathing frequency (BF)and the main indicator of energy expenditure VO2. VO2 values ??were then converted to calories, as indicators of energy intensity. Based on the Wilcoxon test, we investigated whether or not, these values ??between the measurements of the
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
AK - Sport a aktivity volného času
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Outdoor Activities - odborný časopis pro aktivity v přírodě
ISSN
1802-3908
e-ISSN
—
Svazek periodika
5
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
12
Strana od-do
15-26
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—