Diagnostic reliability of the Berlin classification for complex MCA aneurysms-usability in a series of only giant aneurysms
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13450%2F20%3A43895920" target="_blank" >RIV/44555601:13450/20:43895920 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s00701-020-04565-6" target="_blank" >https://link.springer.com/article/10.1007/s00701-020-04565-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00701-020-04565-6" target="_blank" >10.1007/s00701-020-04565-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diagnostic reliability of the Berlin classification for complex MCA aneurysms-usability in a series of only giant aneurysms
Popis výsledku v původním jazyce
Background and objective The main challenge of bypass surgery of complex MCA aneurysms is not the selection of the bypass type but the initial decision-making of how to exclude the affected vessel segment from circulation. To this end, we have previously proposed a classification for complex MCA aneurysms based on the preoperative angiography. The current study aimed to validate this new classification and assess its diagnostic reliability using the giant aneurysm registry as an independent data set. Methods We reviewed the pretreatment neuroimaging of 51 patients with giant (> 2.5 cm) MCA aneurysms from 18 centers, prospectively entered into the international giant aneurysm registry. We classified the aneurysms according to our previously proposed Berlin classification for complex MCA aneurysms. To test for interrater diagnostic reliability, the data set was reviewed by four independent observers. Results We were able to classify all 51 aneurysms according to the Berlin classification for complex MCA aneurysms. Eight percent of the aneurysm were classified as type 1a, 14% as type 1b, 14% as type 2a, 24% as type 2b, 33% as type 2c, and 8% as type 3. The interrater reliability was moderate with Fleiss's Kappa of 0.419. Conclusion The recently published Berlin classification for complex MCA aneurysms showed diagnostic reliability, independent of the observer when applied to the MCA aneurysms of the international giant aneurysm registry.
Název v anglickém jazyce
Diagnostic reliability of the Berlin classification for complex MCA aneurysms-usability in a series of only giant aneurysms
Popis výsledku anglicky
Background and objective The main challenge of bypass surgery of complex MCA aneurysms is not the selection of the bypass type but the initial decision-making of how to exclude the affected vessel segment from circulation. To this end, we have previously proposed a classification for complex MCA aneurysms based on the preoperative angiography. The current study aimed to validate this new classification and assess its diagnostic reliability using the giant aneurysm registry as an independent data set. Methods We reviewed the pretreatment neuroimaging of 51 patients with giant (> 2.5 cm) MCA aneurysms from 18 centers, prospectively entered into the international giant aneurysm registry. We classified the aneurysms according to our previously proposed Berlin classification for complex MCA aneurysms. To test for interrater diagnostic reliability, the data set was reviewed by four independent observers. Results We were able to classify all 51 aneurysms according to the Berlin classification for complex MCA aneurysms. Eight percent of the aneurysm were classified as type 1a, 14% as type 1b, 14% as type 2a, 24% as type 2b, 33% as type 2c, and 8% as type 3. The interrater reliability was moderate with Fleiss's Kappa of 0.419. Conclusion The recently published Berlin classification for complex MCA aneurysms showed diagnostic reliability, independent of the observer when applied to the MCA aneurysms of the international giant aneurysm registry.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Neurochirurgica
ISSN
0001-6268
e-ISSN
—
Svazek periodika
162
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
6
Strana od-do
2753-2758
Kód UT WoS článku
000569298600002
EID výsledku v databázi Scopus
—