Quantitative Gait Analysis of Patients with Severe Symptomatic Spinal Stenosis Utilizing the Gait Profile Score: An Observational Clinical Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13450%2F22%3A43897298" target="_blank" >RIV/44555601:13450/22:43897298 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/22:10441478
Výsledek na webu
<a href="https://www.mdpi.com/1424-8220/22/4/1633" target="_blank" >https://www.mdpi.com/1424-8220/22/4/1633</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s22041633" target="_blank" >10.3390/s22041633</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quantitative Gait Analysis of Patients with Severe Symptomatic Spinal Stenosis Utilizing the Gait Profile Score: An Observational Clinical Study
Popis výsledku v původním jazyce
Lumbar spine stenosis (LSS) typically manifests with neurogenic claudication, altering patients' gait. The use of optoelectronic systems has allowed clinicians to perform 3D quantitative gait analysis to quantify and understand these alterations. Although several authors have presented analysis of spatiotemporal gait parameters, data concerning kinematic parameters is lacking. Fifteen patients with LSS were matched with 15 healthy controls. Quantitative gait analysis utilizing optoelectronic techniques was performed for each pair of subjects in a specialized laboratory. Statistical comparison of patients and controls was performed to determine differences in spatiotemporal parameters and the Gait Profile Score (GPS). Statistically significant differences were found between patient and control groups for all spatiotemporal parameters. Patients had significantly different overall GPS (p = 0.004) and had limited internal/external pelvic rotation (p < 0.001) and cranial/caudal movement (p = 0.034), limited hip extension (p = 0.012) and abduction/adduction (p = 0.012) and limited ankle plantar flexion (p < 0.001). In conclusion, patients with LSS have significantly altered gait patterns in three regions (pelvis, hip and ankle) compared to healthy controls. Analysis of kinematic graphs has given insight into gait pathophysiology of patients with LSS and the use of GPS will allow us to quantify surgical results in the future.
Název v anglickém jazyce
Quantitative Gait Analysis of Patients with Severe Symptomatic Spinal Stenosis Utilizing the Gait Profile Score: An Observational Clinical Study
Popis výsledku anglicky
Lumbar spine stenosis (LSS) typically manifests with neurogenic claudication, altering patients' gait. The use of optoelectronic systems has allowed clinicians to perform 3D quantitative gait analysis to quantify and understand these alterations. Although several authors have presented analysis of spatiotemporal gait parameters, data concerning kinematic parameters is lacking. Fifteen patients with LSS were matched with 15 healthy controls. Quantitative gait analysis utilizing optoelectronic techniques was performed for each pair of subjects in a specialized laboratory. Statistical comparison of patients and controls was performed to determine differences in spatiotemporal parameters and the Gait Profile Score (GPS). Statistically significant differences were found between patient and control groups for all spatiotemporal parameters. Patients had significantly different overall GPS (p = 0.004) and had limited internal/external pelvic rotation (p < 0.001) and cranial/caudal movement (p = 0.034), limited hip extension (p = 0.012) and abduction/adduction (p = 0.012) and limited ankle plantar flexion (p < 0.001). In conclusion, patients with LSS have significantly altered gait patterns in three regions (pelvis, hip and ankle) compared to healthy controls. Analysis of kinematic graphs has given insight into gait pathophysiology of patients with LSS and the use of GPS will allow us to quantify surgical results in the future.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10403 - Physical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors
ISSN
1424-8220
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
18
Strana od-do
1-17
Kód UT WoS článku
000763275800001
EID výsledku v databázi Scopus
—