Analysis of Means (ANOM) as a Tool for Comparison of Sample Treatment Methods: Testing Various Mineralization Procedures for Selenium Determination in Biological Materials
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44994575%3A_____%2F17%3AN0000008" target="_blank" >RIV/44994575:_____/17:N0000008 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.5740/jaoacint.16-0258" target="_blank" >http://dx.doi.org/10.5740/jaoacint.16-0258</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5740/jaoacint.16-0258" target="_blank" >10.5740/jaoacint.16-0258</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of Means (ANOM) as a Tool for Comparison of Sample Treatment Methods: Testing Various Mineralization Procedures for Selenium Determination in Biological Materials
Popis výsledku v původním jazyce
Several mineralization methods for the determination of selenium using hydride generation optical emission spectrometry with inductively coupled plasma in biological samples (whole egg powder and pork liver) were compared using the analysis of means (ANOM) method. This statistical tool is suitable for graphical representation of testing on simple comparative experiments. The results yielded by ANOM are identical with those obtained with the commonly used analysis of variance (ANOVA) method; however, the graphical output of ANOM is more illustrative in comparison to ANOVA. Both methods indicated a significant discrepancy between the results obtained using muffle furnace ashing mineralization and the results provided by other mineralization methods. This is probably due to the loss of volatile selenium compounds during the decomposition of organic matter.
Název v anglickém jazyce
Analysis of Means (ANOM) as a Tool for Comparison of Sample Treatment Methods: Testing Various Mineralization Procedures for Selenium Determination in Biological Materials
Popis výsledku anglicky
Several mineralization methods for the determination of selenium using hydride generation optical emission spectrometry with inductively coupled plasma in biological samples (whole egg powder and pork liver) were compared using the analysis of means (ANOM) method. This statistical tool is suitable for graphical representation of testing on simple comparative experiments. The results yielded by ANOM are identical with those obtained with the commonly used analysis of variance (ANOVA) method; however, the graphical output of ANOM is more illustrative in comparison to ANOVA. Both methods indicated a significant discrepancy between the results obtained using muffle furnace ashing mineralization and the results provided by other mineralization methods. This is probably due to the loss of volatile selenium compounds during the decomposition of organic matter.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0064" target="_blank" >ED2.1.00/03.0064: Dopravní VaV centrum</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF AOAC INTERNATIONAL
ISSN
1060-3271
e-ISSN
—
Svazek periodika
100
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
236-240
Kód UT WoS článku
000392041200031