Analysis of the Influence of PAR Elevation on its Performance Using a LP Code MELCOR 1.8.6
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46356088%3A_____%2F10%3A%230001203" target="_blank" >RIV/46356088:_____/10:#0001203 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of the Influence of PAR Elevation on its Performance Using a LP Code MELCOR 1.8.6
Popis výsledku v původním jazyce
Recently, within the frame of the OECD/NEA THAI program, it has been demonstrated that the lumped parameter code MELCOR 1.8.6 is suitable for simulating PAR unit operation under various atmospheric conditions. The tests selected for the code validation were the Hydrogen Recombination experiments HR-3 and HR-12, which are characterized, respectively, by ambient temperature, slightly elevated pressure and no steam content and elevated temperature, elevated pressure and saturated atmosphere. During the HR-3 test a spontaneous hydrogen deflagration occurred, which, however, was not modeled by MELCOR. The HR-12 test was, on its turn, characterized by oxygen starvation conditions, which were due to high steam content in the THAI test vessel. Presented at OECD/NEA THAI Project Concluding Seminar, Issy-les-Moulineaux, France, 6.10.2010.
Název v anglickém jazyce
Analysis of the Influence of PAR Elevation on its Performance Using a LP Code MELCOR 1.8.6
Popis výsledku anglicky
Recently, within the frame of the OECD/NEA THAI program, it has been demonstrated that the lumped parameter code MELCOR 1.8.6 is suitable for simulating PAR unit operation under various atmospheric conditions. The tests selected for the code validation were the Hydrogen Recombination experiments HR-3 and HR-12, which are characterized, respectively, by ambient temperature, slightly elevated pressure and no steam content and elevated temperature, elevated pressure and saturated atmosphere. During the HR-3 test a spontaneous hydrogen deflagration occurred, which, however, was not modeled by MELCOR. The HR-12 test was, on its turn, characterized by oxygen starvation conditions, which were due to high steam content in the THAI test vessel. Presented at OECD/NEA THAI Project Concluding Seminar, Issy-les-Moulineaux, France, 6.10.2010.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LA326" target="_blank" >LA326: Zajištění účasti v projektu OECD-NEA THAI</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů