The influence of mechanical stress on cable service life-time
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46356088%3A_____%2F11%3A%230001119" target="_blank" >RIV/46356088:_____/11:#0001119 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.polymertesting.2011.06.005" target="_blank" >http://dx.doi.org/10.1016/j.polymertesting.2011.06.005</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.polymertesting.2011.06.005" target="_blank" >10.1016/j.polymertesting.2011.06.005</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The influence of mechanical stress on cable service life-time
Popis výsledku v původním jazyce
A safety-related cable currently used in nuclear power plants was exposed to accelerated aging to simulate its long-term operation at a temperature of 55 degrees C and a dose rate of 0.2 Gy/h, including loss of coolant accident (LOCA). We studied the influence of excessive mechanical stress on its rate of degradation. Some of the samples were bent and others were pressed, and the aging results were compared with a control sample aged without any mechanical stress. The results have shown a relatively small effect of the mechanical stress applied during the aging on the cable function and LOCA resistance, compared to the results obtained on a cable aged without mechanical stress.
Název v anglickém jazyce
The influence of mechanical stress on cable service life-time
Popis výsledku anglicky
A safety-related cable currently used in nuclear power plants was exposed to accelerated aging to simulate its long-term operation at a temperature of 55 degrees C and a dose rate of 0.2 Gy/h, including loss of coolant accident (LOCA). We studied the influence of excessive mechanical stress on its rate of degradation. Some of the samples were bent and others were pressed, and the aging results were compared with a control sample aged without any mechanical stress. The results have shown a relatively small effect of the mechanical stress applied during the aging on the cable function and LOCA resistance, compared to the results obtained on a cable aged without mechanical stress.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JL - Únava materiálu a lomová mechanika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FT-TA4%2F083" target="_blank" >FT-TA4/083: Bezpečnostní a legislativní aspekty výstavby a spouštění JE nové generace pro energetiku ČR.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Polymer Testing
ISSN
0142-9418
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
709-715
Kód UT WoS článku
000295244200003