Gas entrainment by one single French PWR spray SARNET-2 SPRAY benchmark
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46356088%3A_____%2F13%3A%230001426" target="_blank" >RIV/46356088:_____/13:#0001426 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Gas entrainment by one single French PWR spray SARNET-2 SPRAY benchmark
Popis výsledku v původním jazyce
This paper presents a benchmark performed in the frame of the SARNET-2 project, dealing with momentum transfer between a real-scale PWR spray and the surrounding gas. It presents a description of the IRSN tests on the CALIST facility, the participating codes (8 contributions), code-experiment and code-tocode comparisons. It is found that droplet velocities are almost well calculated one meter below the spray nozzle, even if the spread of the spray is not recovered. However, the values of the entrained gas velocity vary up to 100% from one code to another. Concerning sensitivity analysis, several "simplifications" have been made by the contributors, especially based on the boundary conditions applied at the location where droplets and gas are injected.We have shown here that such simplifications influence droplet and entrained gas characteristics. The next step will be to translate these conclusions in terms of variables representative of interesting parameters for nuclear safety.
Název v anglickém jazyce
Gas entrainment by one single French PWR spray SARNET-2 SPRAY benchmark
Popis výsledku anglicky
This paper presents a benchmark performed in the frame of the SARNET-2 project, dealing with momentum transfer between a real-scale PWR spray and the surrounding gas. It presents a description of the IRSN tests on the CALIST facility, the participating codes (8 contributions), code-experiment and code-tocode comparisons. It is found that droplet velocities are almost well calculated one meter below the spray nozzle, even if the spread of the spray is not recovered. However, the values of the entrained gas velocity vary up to 100% from one code to another. Concerning sensitivity analysis, several "simplifications" have been made by the contributors, especially based on the boundary conditions applied at the location where droplets and gas are injected.We have shown here that such simplifications influence droplet and entrained gas characteristics. The next step will be to translate these conclusions in terms of variables representative of interesting parameters for nuclear safety.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 15th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-15)
ISBN
978-88-902391-2-0
ISSN
—
e-ISSN
—
Počet stran výsledku
13
Strana od-do
—
Název nakladatele
—
Místo vydání
Pisa, Italy
Místo konání akce
Pisa, Italy
Datum konání akce
1. 1. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—