Structural aspect of corium spill on VVER-1000 reactor pit floor slab
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46356088%3A_____%2F18%3AN0000016" target="_blank" >RIV/46356088:_____/18:N0000016 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21110/18:00323035
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.pnucene.2018.04.026" target="_blank" >http://dx.doi.org/10.1016/j.pnucene.2018.04.026</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.pnucene.2018.04.026" target="_blank" >10.1016/j.pnucene.2018.04.026</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Structural aspect of corium spill on VVER-1000 reactor pit floor slab
Popis výsledku v původním jazyce
This paper provides a brief but pointed description of the possibly neglected structural aspect of corium spill on the concrete floor slab of the reactor pit. The corium-concrete interaction is by now a well-studied phenomenon which is considered the key parameter for determining the ablation rate in the floor slab. What has not been reported in the literature so far is the effect of the progressing ablation, the extremely high temperature and the uneven thermal gradient on the static performance of the reinforced concrete floor slab. It was discovered that the structural considerations lead to a different mode of failure as well as to much faster progress of the expected collapse of the reactor pit floor slab.
Název v anglickém jazyce
Structural aspect of corium spill on VVER-1000 reactor pit floor slab
Popis výsledku anglicky
This paper provides a brief but pointed description of the possibly neglected structural aspect of corium spill on the concrete floor slab of the reactor pit. The corium-concrete interaction is by now a well-studied phenomenon which is considered the key parameter for determining the ablation rate in the floor slab. What has not been reported in the literature so far is the effect of the progressing ablation, the extremely high temperature and the uneven thermal gradient on the static performance of the reinforced concrete floor slab. It was discovered that the structural considerations lead to a different mode of failure as well as to much faster progress of the expected collapse of the reactor pit floor slab.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-11753S" target="_blank" >GA15-11753S: Intuitivní materiálové modelování pomocí fuzzy logiky</a><br>
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Progress in Nuclear Energy
ISSN
0149-1970
e-ISSN
—
Svazek periodika
107
Číslo periodika v rámci svazku
August
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
148-154
Kód UT WoS článku
000434754400017
EID výsledku v databázi Scopus
2-s2.0-85046630423