A Wireless Gamma-Ray Monitoring System for Cemented Radwaste Drums
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46356088%3A_____%2F24%3AN0000010" target="_blank" >RIV/46356088:_____/24:N0000010 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/1424-8220/24/7/2332" target="_blank" >https://www.mdpi.com/1424-8220/24/7/2332</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s24072332" target="_blank" >10.3390/s24072332</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Wireless Gamma-Ray Monitoring System for Cemented Radwaste Drums
Popis výsledku v původním jazyce
In the framework of the PREDIS EU project, a wireless battery-operated gamma-ray detection system was developed in order to provide a medium-to-long-term monitoring system for radioactive waste drums. It was initially proposed to monitor the gamma radioactivity outcoming from steel drums containing cemented radwaste, even though it could be usefully employed in a wider range of applications. Gamma rays are penetrating and convey information from the drum's internal structure, as the count rate measured on the surface depends on the thickness and density of the crossed materials. A number of sensors arranged around a drum, typically four units, provide indications of the emission anisotropy, and any sensitive change in the measured count rate would hint at some anomaly, thus triggering a suitable inspection by operators.
Název v anglickém jazyce
A Wireless Gamma-Ray Monitoring System for Cemented Radwaste Drums
Popis výsledku anglicky
In the framework of the PREDIS EU project, a wireless battery-operated gamma-ray detection system was developed in order to provide a medium-to-long-term monitoring system for radioactive waste drums. It was initially proposed to monitor the gamma radioactivity outcoming from steel drums containing cemented radwaste, even though it could be usefully employed in a wider range of applications. Gamma rays are penetrating and convey information from the drum's internal structure, as the count rate measured on the surface depends on the thickness and density of the crossed materials. A number of sensors arranged around a drum, typically four units, provide indications of the emission anisotropy, and any sensitive change in the measured count rate would hint at some anomaly, thus triggering a suitable inspection by operators.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors
ISSN
1424-8220
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
17
Strana od-do
1-17
Kód UT WoS článku
001201158500001
EID výsledku v databázi Scopus
2-s2.0-85190266977