Multi-angle light scattering and viscometric detection for polymer characterization
Popis výsledku v původním jazyce
Multi-angle light scattering (MALS) photometers are becoming common detectors in size exclusion (SEC) chromatography. They effectively solve the crucial problem of SEC, i.e. the column calibration. It has become a common practice that SEC calibration obtained by polystyrene (or other) standards is generally applied to other polymer samples. This practice often results in generation of completely misleading results. The paper shows that in case of a MALS detector the true molar mass is measured directlywithout need for standards or parameters of universal calibration. Since the molar mass is measured independently of SEC separation, the results are significantly less sensitive to instrumental parameters such a flow rate, temperature, injected mass or column performance. Another advantage of MALS detector is possibility to evaluate directly the quality of SEC separation and reveal undesirable interactions of polymer with column packing.
Název v anglickém jazyce
Multi-angle light scattering and viscometric detection for polymer characterization
Popis výsledku anglicky
Multi-angle light scattering (MALS) photometers are becoming common detectors in size exclusion (SEC) chromatography. They effectively solve the crucial problem of SEC, i.e. the column calibration. It has become a common practice that SEC calibration obtained by polystyrene (or other) standards is generally applied to other polymer samples. This practice often results in generation of completely misleading results. The paper shows that in case of a MALS detector the true molar mass is measured directlywithout need for standards or parameters of universal calibration. Since the molar mass is measured independently of SEC separation, the results are significantly less sensitive to instrumental parameters such a flow rate, temperature, injected mass or column performance. Another advantage of MALS detector is possibility to evaluate directly the quality of SEC separation and reveal undesirable interactions of polymer with column packing.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CD - Makromolekulární chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/FT-TA2%2F006" target="_blank" >FT-TA2/006: *Nové nátěrové hmoty pro vybrané stavební technologie.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advanced Polymeric Material (APM-2006)
ISBN
80-968433-3-8
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
—
Název nakladatele
SUZA
Místo vydání
Bratislava
Místo konání akce
Bratislava
Datum konání akce
11. 6. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—