Ohybová tuhost fraktury dens axis stabilisovaná jedním kortikálním šroubem - numerický přístup
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F07%3A%40KMP0063" target="_blank" >RIV/46747885:24210/07:@KMP0063 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bending stiffness of odontoid fracture fixation with one cortical screw - numerical approach
Popis výsledku v původním jazyce
The anterior screw fixation of odontoid fractures is nowadays standard clinical operation. There are less biomechanical studies dealing with the problem whether on or two screws should be used for this type of stabilisation. This study used in vitro experiment and finite element simulation to investigate the bending stiffness in the midsagital plane of stabilised odontoid fracture type II of the second cervical vertebra. The comparative study of one cortical screw and the cannulated one was performed. The results indicated that there are no significant differences between them. In addition from the bending stiffness point of view, tightening the screw to higher levels is quite useless, because the stiffness is not higher, but with higher stresses we can reached diminishing of the bone?s strength and stiffness, according to Wolff?s law of functional adaptation. Thus the most reasonable might be to tighten the screws to certain moment, as in the dental surgery is performed.
Název v anglickém jazyce
Bending stiffness of odontoid fracture fixation with one cortical screw - numerical approach
Popis výsledku anglicky
The anterior screw fixation of odontoid fractures is nowadays standard clinical operation. There are less biomechanical studies dealing with the problem whether on or two screws should be used for this type of stabilisation. This study used in vitro experiment and finite element simulation to investigate the bending stiffness in the midsagital plane of stabilised odontoid fracture type II of the second cervical vertebra. The comparative study of one cortical screw and the cannulated one was performed. The results indicated that there are no significant differences between them. In addition from the bending stiffness point of view, tightening the screw to higher levels is quite useless, because the stiffness is not higher, but with higher stresses we can reached diminishing of the bone?s strength and stiffness, according to Wolff?s law of functional adaptation. Thus the most reasonable might be to tighten the screws to certain moment, as in the dental surgery is performed.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
IFMBE Proceedings
ISBN
978-3-540-73043-9
Počet stran výsledku
3
Strana od-do
270-273
Počet stran knihy
—
Název nakladatele
Springer Berlin Heidelberg
Místo vydání
Berlin Heidelberg
Kód UT WoS kapitoly
—