Continuity Oxygen Activity and Type Nodulizier for Ductile Iron Production
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F09%3A%230001160" target="_blank" >RIV/46747885:24210/09:#0001160 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Continuity Oxygen Activity and Type Nodulizier for Ductile Iron Production
Popis výsledku v původním jazyce
The article deals with measurements of oxygen activity ductile iron. The oxygen activity measurement proved, that oxygen activity in molted iron depends on technology of melting, chemical composition and temperature of the melt. The methodology of the oxygen activity measurement using TERMOSONDY Kladno TSO-FS (combined) sensors was developed at the Department of Engineering Technology Technical University of Liberec. The sensors were originally assigned for very low oxygen activity measured in molted steel. The EMF (ElectroMotive Force) and the temperature are sensor?s output parameters used for oxygen activity calculation. Measured data are processed by the computer and results are displayed on the screen. All the results are saved in computer?s memory together with the time of measurement. Oxygen activity is calculated using two formulas (ČSAV Ostrava and Electro Nite c.o.) at the time.
Název v anglickém jazyce
Continuity Oxygen Activity and Type Nodulizier for Ductile Iron Production
Popis výsledku anglicky
The article deals with measurements of oxygen activity ductile iron. The oxygen activity measurement proved, that oxygen activity in molted iron depends on technology of melting, chemical composition and temperature of the melt. The methodology of the oxygen activity measurement using TERMOSONDY Kladno TSO-FS (combined) sensors was developed at the Department of Engineering Technology Technical University of Liberec. The sensors were originally assigned for very low oxygen activity measured in molted steel. The EMF (ElectroMotive Force) and the temperature are sensor?s output parameters used for oxygen activity calculation. Measured data are processed by the computer and results are displayed on the screen. All the results are saved in computer?s memory together with the time of measurement. Oxygen activity is calculated using two formulas (ČSAV Ostrava and Electro Nite c.o.) at the time.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Transactions of the VŠB - Technical University of Ostrava
ISSN
0474-8484
e-ISSN
—
Svazek periodika
LII
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—