Design of experimental setup for investigation of cavitation bubble collapse close to a solid wall
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F10%3A%230001632" target="_blank" >RIV/46747885:24210/10:#0001632 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design of experimental setup for investigation of cavitation bubble collapse close to a solid wall
Popis výsledku v původním jazyce
The article describes experimental setup for investigation of the impact load from collapsing cavitation bubble on a solid wall. A vapour bubble is generated inside a cubic chamber by local heating of water inside a thin channel in a button. The bubble collapse is initiated by a piezoelectric actuator attached to the flexible wall of the chamber. A laser diode with a linear CCD sensor are used to detect the bubble position during its buoyancy-driven rise to the upper wall of the chamber. The bubble collapse impact load is measured using a PVDF piezoelectric transducer glued to the upper wall of the chamber and recorded by high-speed CCD camera illuminated by a high-power LED diode. The pressure inside the chamber is measured by the dynamic pressure transducer. All the system components are controlled and synchronized by an oscilloscope and pulse generator using the LabView software.
Název v anglickém jazyce
Design of experimental setup for investigation of cavitation bubble collapse close to a solid wall
Popis výsledku anglicky
The article describes experimental setup for investigation of the impact load from collapsing cavitation bubble on a solid wall. A vapour bubble is generated inside a cubic chamber by local heating of water inside a thin channel in a button. The bubble collapse is initiated by a piezoelectric actuator attached to the flexible wall of the chamber. A laser diode with a linear CCD sensor are used to detect the bubble position during its buoyancy-driven rise to the upper wall of the chamber. The bubble collapse impact load is measured using a PVDF piezoelectric transducer glued to the upper wall of the chamber and recorded by high-speed CCD camera illuminated by a high-power LED diode. The pressure inside the chamber is measured by the dynamic pressure transducer. All the system components are controlled and synchronized by an oscilloscope and pulse generator using the LabView software.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP101%2F10%2F1428" target="_blank" >GAP101/10/1428: Mechanizmy kolapsu a štěpení ultrazvukem buzených kavitačních bublin v blízkosti pevné stěny v Newtonské kapalině</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Conference Experimental Fluid Mechanics 2010 Conference Proceedings
ISBN
9788073726706
ISSN
—
e-ISSN
—
Počet stran výsledku
852
Strana od-do
—
Název nakladatele
Technická univerzita v Liberci
Místo vydání
Technická univerzita v Liberci
Místo konání akce
Ještěd, Liberec
Datum konání akce
1. 1. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—