Popis výsledku v původním jazyce
The standard ISO 6358 is often used for describing flow rate of pneumatic valves. This standard uses sonic conductance and the critical pressure ratio to calculate mentioned flow rate. Different valves can be compared by these two parameters and an accurate mathematical model of flow rate can be created for an actual valve. The presented work is based on the measurements of the charge and the discharge of a tank through a valve. Downstream pressure, upstream pressure, temperature for both supply air andpressurized air inside the tank are monitored. The sonic conductance and the critical pressure ratio are obtained from this process as inverse models for two valves. The work presented in this paper was supported by the Students Grant Project Control ofFluid Servosystems in Technical University of Liberec and we would like to thank the Aalto University - Finland for measurements of flow rate characteristic with the tank.
Název v anglickém jazyce
Determination of flow rate characteristic for pneumatic valves
Popis výsledku anglicky
The standard ISO 6358 is often used for describing flow rate of pneumatic valves. This standard uses sonic conductance and the critical pressure ratio to calculate mentioned flow rate. Different valves can be compared by these two parameters and an accurate mathematical model of flow rate can be created for an actual valve. The presented work is based on the measurements of the charge and the discharge of a tank through a valve. Downstream pressure, upstream pressure, temperature for both supply air andpressurized air inside the tank are monitored. The sonic conductance and the critical pressure ratio are obtained from this process as inverse models for two valves. The work presented in this paper was supported by the Students Grant Project Control ofFluid Servosystems in Technical University of Liberec and we would like to thank the Aalto University - Finland for measurements of flow rate characteristic with the tank.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Experimental Fluid Mechanics
ISBN
978-80-7372-784-0
ISSN
—
e-ISSN
—
Počet stran výsledku
12
Strana od-do
468-479
Název nakladatele
Technical University of Liberec
Místo vydání
Liberec
Místo konání akce
Jičín
Datum konání akce
22. 9. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—