Influence of the Spatial Orientation of the Standing?Wave Thermoacoustic Prime Mover
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F12%3A%230002679" target="_blank" >RIV/46747885:24210/12:#0002679 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of the Spatial Orientation of the Standing?Wave Thermoacoustic Prime Mover
Popis výsledku v původním jazyce
Motivation of this study was to show the effect of spatial orientation of the standing?wave thermoacoustic prime mover working with the atmospheric air on its performance in steady?state and on onset characteristics. Two?microphone method was used for measuring of an acoustic power for its simplicity and temperature distribution was monitored by several thermocouples. The experimental results indicate positive effect of natural convection on steady?state acoustic power and magnitude of onset temperaturegradient for positions with hot heat exchanger under heat sink relative to gravity and also negative affection for position with the bottom up. This finding is an important step to design the thermoacoustic engines driven by waste heat energy or miniature MEMS based thermoacoustic refrigerator for thermal management of micro electronic devices.
Název v anglickém jazyce
Influence of the Spatial Orientation of the Standing?Wave Thermoacoustic Prime Mover
Popis výsledku anglicky
Motivation of this study was to show the effect of spatial orientation of the standing?wave thermoacoustic prime mover working with the atmospheric air on its performance in steady?state and on onset characteristics. Two?microphone method was used for measuring of an acoustic power for its simplicity and temperature distribution was monitored by several thermocouples. The experimental results indicate positive effect of natural convection on steady?state acoustic power and magnitude of onset temperaturegradient for positions with hot heat exchanger under heat sink relative to gravity and also negative affection for position with the bottom up. This finding is an important step to design the thermoacoustic engines driven by waste heat energy or miniature MEMS based thermoacoustic refrigerator for thermal management of micro electronic devices.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GCP101%2F11%2FJ019" target="_blank" >GCP101/11/J019: Termoakustický motor</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Conference EXPERIMENTAL FLUID MECHANICS 2012 Conference Proceedings
ISBN
978-80-7372-912-7
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
524-531
Název nakladatele
Technical university of Liberec
Místo vydání
—
Místo konání akce
Hradec Králové
Datum konání akce
1. 1. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—