Effect of Experimental Factors on Hardness Measurement Using the UCI Technique
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F14%3A%230006395" target="_blank" >RIV/46747885:24210/14:#0006395 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.scientific.net/MSF.782.61" target="_blank" >http://www.scientific.net/MSF.782.61</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/MSF.782.61" target="_blank" >10.4028/www.scientific.net/MSF.782.61</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of Experimental Factors on Hardness Measurement Using the UCI Technique
Popis výsledku v původním jazyce
The work experimentally analyses the effect of various factors on measured hardness values on thin steel sheets by Ultrasonic Contact Impedance (UCI) technique. The conditions experimentally used are compared with that according the ASTM A 1038-08 standard. UCI is an experimental technique for indirect hardness measurement. The equipment uses a Vickers indenter and the hardness measurement is based on the change of the resonance frequency during indenter´s penetration [1]. The UCI hardness may depend onsome factors, therefore optimal measurement conditions must be determined. The effect of distance between indents, zinc coating, sample weight, sample mounting and adhesive material for sample fixation was determined
Název v anglickém jazyce
Effect of Experimental Factors on Hardness Measurement Using the UCI Technique
Popis výsledku anglicky
The work experimentally analyses the effect of various factors on measured hardness values on thin steel sheets by Ultrasonic Contact Impedance (UCI) technique. The conditions experimentally used are compared with that according the ASTM A 1038-08 standard. UCI is an experimental technique for indirect hardness measurement. The equipment uses a Vickers indenter and the hardness measurement is based on the change of the resonance frequency during indenter´s penetration [1]. The UCI hardness may depend onsome factors, therefore optimal measurement conditions must be determined. The effect of distance between indents, zinc coating, sample weight, sample mounting and adhesive material for sample fixation was determined
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0024" target="_blank" >EE2.3.30.0024: Rozvoj řešitelských týmů projektů VaV na Technické univerzitě v Liberci</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Materials Science Forum Vol. 782 (2014) Metalography XV
ISBN
978-3-03835-072-9
ISSN
0255-5476
e-ISSN
—
Počet stran výsledku
4
Strana od-do
61-64
Název nakladatele
TRANS TECH PUBLICATIONS LTD, LAUBLSRUTISTR 24, CH-8717 STAFA-ZURICH, SWITZERLAND
Místo vydání
Zurich
Místo konání akce
Stara Lesna, SLOVAKIA
Datum konání akce
24. 4. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000338978600010