Test report of the electrical components thermal-vibration test
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F15%3A00002697" target="_blank" >RIV/46747885:24210/15:00002697 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.tul.cz" target="_blank" >http://www.tul.cz</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Test report of the electrical components thermal-vibration test
Popis výsledku v původním jazyce
Electrical components used in vehicles or trains are exposed to vibrations during the vehicle driving. Their perfect anchoring in the cases is important for their reliable operation and disorders minimization. The resistance of fasteners against vibration testing is necessary during their new type development. Basic vibration test is performed at normal temperature and vibrations exposure is for each vehicle or train type defined by the standard EN 60068-2-6. Because a large temperature range can be achieved during real operation, the cases and components are exposed to the combined loading by vibrations and temperature. The elements thermal expansion may negatively affect the used fasteners reliability. Therefore, most producers perform vibrations test at various temperatures to minimize this risk.
Název v anglickém jazyce
Test report of the electrical components thermal-vibration test
Popis výsledku anglicky
Electrical components used in vehicles or trains are exposed to vibrations during the vehicle driving. Their perfect anchoring in the cases is important for their reliable operation and disorders minimization. The resistance of fasteners against vibration testing is necessary during their new type development. Basic vibration test is performed at normal temperature and vibrations exposure is for each vehicle or train type defined by the standard EN 60068-2-6. Because a large temperature range can be achieved during real operation, the cases and components are exposed to the combined loading by vibrations and temperature. The elements thermal expansion may negatively affect the used fasteners reliability. Therefore, most producers perform vibrations test at various temperatures to minimize this risk.
Klasifikace
Druh
V<sub>souhrn</sub> - Souhrnná výzkumná zpráva
CEP obor
JS - Řízení spolehlivosti a kvality, zkušebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
C - Předmět řešení projektu podléhá obchodnímu tajemství (§ 504 Občanského zákoníku), ale název projektu, cíle projektu a u ukončeného nebo zastaveného projektu zhodnocení výsledku řešení projektu (údaje P03, P04, P15, P19, P29, PN8) dodané do CEP, jsou upraveny tak, aby byly zveřejnitelné.
Údaje specifické pro druh výsledku
Počet stran výsledku
8
Místo vydání
—
Název nakladatele resp. objednatele
BV elektronik spol. s r.o., Vysokomýtská 1104, 534 01 Holice v Čechách