Evaluation of acetabular cup initial fixation by using resonance frequency principle
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F15%3A00002940" target="_blank" >RIV/46747885:24210/15:00002940 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00179906:_____/15:10319488
Výsledek na webu
<a href="http://dx.doi.org/10.1177/0954411914561485" target="_blank" >http://dx.doi.org/10.1177/0954411914561485</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/0954411914561485" target="_blank" >10.1177/0954411914561485</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of acetabular cup initial fixation by using resonance frequency principle
Popis výsledku v původním jazyce
The clinical practice shows that the loosening of acetabular cups is more frequent than stem loosening. With standard cups, the incidence of dislocation failure is highest in the first year after arthroplasty implantation. The aim of the study was to quantitatively evaluate the implant-bone stability of a cementless acetabular cup prosthesis by using a device based on resonance frequency analysis. The evaluation of this device was done by finite element analysis and in vitro experiments. It was shown that not all the resonance frequencies can be measured by our device. The resonance frequencies vary within the range of 500-3000Hz. The proposed power spectrum measurement gives the information about the absolute stiffness of the press-fit implant..
Název v anglickém jazyce
Evaluation of acetabular cup initial fixation by using resonance frequency principle
Popis výsledku anglicky
The clinical practice shows that the loosening of acetabular cups is more frequent than stem loosening. With standard cups, the incidence of dislocation failure is highest in the first year after arthroplasty implantation. The aim of the study was to quantitatively evaluate the implant-bone stability of a cementless acetabular cup prosthesis by using a device based on resonance frequency analysis. The evaluation of this device was done by finite element analysis and in vitro experiments. It was shown that not all the resonance frequencies can be measured by our device. The resonance frequencies vary within the range of 500-3000Hz. The proposed power spectrum measurement gives the information about the absolute stiffness of the press-fit implant..
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010879" target="_blank" >TA01010879: Vývoj prototypu přístroje pro zjišťování primární stability totálních náhrad kyčelních kloubů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
ISSN
0954-4119
e-ISSN
—
Svazek periodika
229
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
3-8
Kód UT WoS článku
000349435600001
EID výsledku v databázi Scopus
2-s2.0-84930442529