Evaluating the moisture transfer of membranes for total heat exchanger
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F17%3A00004147" target="_blank" >RIV/46747885:24210/17:00004147 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.epj-conferences.org/articles/epjconf/abs/2017/12/epjconf_efm2017_02080/epjconf_efm2017_02080.html" target="_blank" >https://www.epj-conferences.org/articles/epjconf/abs/2017/12/epjconf_efm2017_02080/epjconf_efm2017_02080.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/201714302080" target="_blank" >10.1051/epjconf/201714302080</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluating the moisture transfer of membranes for total heat exchanger
Popis výsledku v původním jazyce
This paper presents an experimental evaluation of moisture transfer of a novel membrane which is used in enthalpy heat exchanger. The moister transfer through a membrane was investigated in a model of counter flow heat exchanger and the effectiveness of moister transfer was evaluated for various flow velocities. It was found that the measuring error, i.e. difference between moister absorbed and released is quite high. Therefore, measuring uncertainty analyses were performed. The resulting uncertainty of effectiveness of moister transfer was derived using partial derivatives of all influencing quantities and considering both random and systematic uncertainties. It was found that measuring of mass flow rate has the biggest influence on resulting uncertainty of moister transfer effectiveness. Therefore, accuracy of measured air flow rates measuring must be improved to reach lower resulting uncertainty.
Název v anglickém jazyce
Evaluating the moisture transfer of membranes for total heat exchanger
Popis výsledku anglicky
This paper presents an experimental evaluation of moisture transfer of a novel membrane which is used in enthalpy heat exchanger. The moister transfer through a membrane was investigated in a model of counter flow heat exchanger and the effectiveness of moister transfer was evaluated for various flow velocities. It was found that the measuring error, i.e. difference between moister absorbed and released is quite high. Therefore, measuring uncertainty analyses were performed. The resulting uncertainty of effectiveness of moister transfer was derived using partial derivatives of all influencing quantities and considering both random and systematic uncertainties. It was found that measuring of mass flow rate has the biggest influence on resulting uncertainty of moister transfer effectiveness. Therefore, accuracy of measured air flow rates measuring must be improved to reach lower resulting uncertainty.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences
ISBN
—
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
—
Místo vydání
—
Místo konání akce
Marienbad, Czech Republic
Datum konání akce
1. 1. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000407743800082