© Experimental Stress Analysis - 57th International Scientific Conference, EAN 2019 - Conference Proceedings. All rights reserved. Linear guiding systems are usually dynamically loaded. The similar situation emerges in the bearings of compactors drums. During the tests of the compactors are bearings dynamically loaded and reaction forces are transmitted through the test facility to the ground. For minimization of transmitting dynamic forces and emerging vibrations, is desirable to test the compactors on the suspended test facility. The aim of this paper was to identify initial conditions for the test facility suspension considering minimization of the emerging vibrations. We first identified operating conditions of the compactors-especially a loading uniformity and force amplitude transmitted to the ground. Force distribution we determined by ODS measurement. Force amplitude was calculated through mathematical model as a solution of differential equations. These results were further used for dynamic analysis of the suspension. The dynamic analysis performed showed efficiency of designed suspension. The force amplitude transmitted to the ground decreased significantly.
Název v anglickém jazyce
Measurement and simulation of dynamic systems parameters
Popis výsledku anglicky
© Experimental Stress Analysis - 57th International Scientific Conference, EAN 2019 - Conference Proceedings. All rights reserved. Linear guiding systems are usually dynamically loaded. The similar situation emerges in the bearings of compactors drums. During the tests of the compactors are bearings dynamically loaded and reaction forces are transmitted through the test facility to the ground. For minimization of transmitting dynamic forces and emerging vibrations, is desirable to test the compactors on the suspended test facility. The aim of this paper was to identify initial conditions for the test facility suspension considering minimization of the emerging vibrations. We first identified operating conditions of the compactors-especially a loading uniformity and force amplitude transmitted to the ground. Force distribution we determined by ODS measurement. Force amplitude was calculated through mathematical model as a solution of differential equations. These results were further used for dynamic analysis of the suspension. The dynamic analysis performed showed efficiency of designed suspension. The force amplitude transmitted to the ground decreased significantly.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Experimental Stress Analysis - 57th International Scientific Conference, EAN 2019 - Conference Proceedings
ISBN
978-802145766-9
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
175-178