CFD based design for ejector cooling system using HFOS (1234ze(E) and 1234yf)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F20%3A00008172" target="_blank" >RIV/46747885:24210/20:00008172 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/1996-1073/13/6/1408/pdf" target="_blank" >https://www.mdpi.com/1996-1073/13/6/1408/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/en13061408" target="_blank" >10.3390/en13061408</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CFD based design for ejector cooling system using HFOS (1234ze(E) and 1234yf)
Popis výsledku v původním jazyce
The field of computational fluid dynamics has been rekindled by recent researchers to unleash this powerful tool to predict the ejector design, as well as to analyse and improve its performance. In this paper, CFD simulation was conducted to model a 2-D axisymmetric supersonic ejector using NIST real gas model integrated in ANSYS Fluent to probe the physical insight and consistent with accurate solutions. HFOs (1234ze(E) and 1234yf) were used as working fluids for their promising alternatives, low global warming potential (GWP), and adhering to EU Council regulations. The impact of different operating conditions, performance maps, and the Pareto frontier performance approach were investigated. The expansion ratio of both refrigerants has been accomplished in linear relationship using their critical compression ratio within ±0.30% accuracy. The results show that R1234yf achieved reasonably better overall performance than R1234ze(E). Generally, by increasing the primary flow inlet saturation temperature and pressure, the entrainment ratio will be lower, and this allows for a higher critical operating back pressure. Moreover, it was found out that increasing the degree of superheat for inlet primary flow by 25 K improved the entrainment ratio by almost 20.70% for R1234yf. Conversely, increasing the degree of superheat to the inlet secondary flow has a relativity negative impact on the performance. The maximum overall ejector efficiency reached was 0.372 and 0.364 for R1234yf and R1234ze(E) respectively. Comparing the results using ideal gas model, the ejector entrainment ratio was overestimated up to 50.26% for R1234yf and 25.66% for R1234ze(E) higher than using real gas model.
Název v anglickém jazyce
CFD based design for ejector cooling system using HFOS (1234ze(E) and 1234yf)
Popis výsledku anglicky
The field of computational fluid dynamics has been rekindled by recent researchers to unleash this powerful tool to predict the ejector design, as well as to analyse and improve its performance. In this paper, CFD simulation was conducted to model a 2-D axisymmetric supersonic ejector using NIST real gas model integrated in ANSYS Fluent to probe the physical insight and consistent with accurate solutions. HFOs (1234ze(E) and 1234yf) were used as working fluids for their promising alternatives, low global warming potential (GWP), and adhering to EU Council regulations. The impact of different operating conditions, performance maps, and the Pareto frontier performance approach were investigated. The expansion ratio of both refrigerants has been accomplished in linear relationship using their critical compression ratio within ±0.30% accuracy. The results show that R1234yf achieved reasonably better overall performance than R1234ze(E). Generally, by increasing the primary flow inlet saturation temperature and pressure, the entrainment ratio will be lower, and this allows for a higher critical operating back pressure. Moreover, it was found out that increasing the degree of superheat for inlet primary flow by 25 K improved the entrainment ratio by almost 20.70% for R1234yf. Conversely, increasing the degree of superheat to the inlet secondary flow has a relativity negative impact on the performance. The maximum overall ejector efficiency reached was 0.372 and 0.364 for R1234yf and R1234ze(E) respectively. Comparing the results using ideal gas model, the ejector entrainment ratio was overestimated up to 50.26% for R1234yf and 25.66% for R1234ze(E) higher than using real gas model.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Energies
ISSN
1726-9679
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
724-727
Kód UT WoS článku
000528727500113
EID výsledku v databázi Scopus
2-s2.0-85082523986