Skin effect in conductor of rectangular cross section
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F11%3A%230001772" target="_blank" >RIV/46747885:24220/11:#0001772 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Skin effect in conductor of rectangular cross section
Popis výsledku v původním jazyce
Two approximate formulae for skin effect in conductor of rectangular cross section were derived in the last time. They differ in the current distribution not only in the conductor volume but also on its surface. Since the current distribution in the conductor cannot be measured, we are limited to the measurement of effects on conductor surface and its environment. The potential drop was measured on the surface, but its sensitivity and precision is too low. Therefore flux density of magnetic field generated by current in the conductor was calculated for skin effect and uniform distribution. Then the magnetic field was measured. Unfortunately, at frequency of 1200 Hz where the skin effect was evident the exciting current was to low, to find good agreement with theoretical prediction. However it ii only technical limitation, that will be eliminated in the future.
Název v anglickém jazyce
Skin effect in conductor of rectangular cross section
Popis výsledku anglicky
Two approximate formulae for skin effect in conductor of rectangular cross section were derived in the last time. They differ in the current distribution not only in the conductor volume but also on its surface. Since the current distribution in the conductor cannot be measured, we are limited to the measurement of effects on conductor surface and its environment. The potential drop was measured on the surface, but its sensitivity and precision is too low. Therefore flux density of magnetic field generated by current in the conductor was calculated for skin effect and uniform distribution. Then the magnetic field was measured. Unfortunately, at frequency of 1200 Hz where the skin effect was evident the exciting current was to low, to find good agreement with theoretical prediction. However it ii only technical limitation, that will be eliminated in the future.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD102%2F08%2FH081" target="_blank" >GD102/08/H081: Nestandardní aplikace fyzikálních polí - analogie, modelování, ověřování a simulace</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AMTEE 2011
ISBN
978-80-7043-993-7
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
"II-23"-"II-24"
Název nakladatele
—
Místo vydání
Plzeň
Místo konání akce
Klatovy
Datum konání akce
1. 1. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—