Nonlinear state and unmeasured disturbance estimation for use in power plant superheaters control
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F15%3A%230003489" target="_blank" >RIV/46747885:24220/15:#0003489 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24220/15:00002554
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.proeng.2015.01.526" target="_blank" >http://dx.doi.org/10.1016/j.proeng.2015.01.526</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.proeng.2015.01.526" target="_blank" >10.1016/j.proeng.2015.01.526</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nonlinear state and unmeasured disturbance estimation for use in power plant superheaters control
Popis výsledku v původním jazyce
This paper deals with the state and unmeasured disturbance estimation within the nonlinear model predictive control of the superheated steam temperature in a once-trough boiler of a fossil fuelled power plant. The nonlinear model of the once-trough boiler has very high order, it is significantly nonlinear and load dependent. Model is excited by several disturbances, but not all of them are measured. Particularly the heat of flue gas is unmeasured disturbance which has significant influence on the superheated steam temperature and its estimation could improve the control performances of the superheated steam temperature. The proposed nonlinear state and unmeasured disturbance observer is based on the nonlinear moving horizon estimation algorithm.
Název v anglickém jazyce
Nonlinear state and unmeasured disturbance estimation for use in power plant superheaters control
Popis výsledku anglicky
This paper deals with the state and unmeasured disturbance estimation within the nonlinear model predictive control of the superheated steam temperature in a once-trough boiler of a fossil fuelled power plant. The nonlinear model of the once-trough boiler has very high order, it is significantly nonlinear and load dependent. Model is excited by several disturbances, but not all of them are measured. Particularly the heat of flue gas is unmeasured disturbance which has significant influence on the superheated steam temperature and its estimation could improve the control performances of the superheated steam temperature. The proposed nonlinear state and unmeasured disturbance observer is based on the nonlinear moving horizon estimation algorithm.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BC - Teorie a systémy řízení
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA02020109" target="_blank" >TA02020109: Prediktivní řídicí systém pro zlepšení stability a zvýšení účinnosti elektrárenských bloků</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Energy Procedia
ISBN
—
ISSN
1876-6102
e-ISSN
—
Počet stran výsledku
7
Strana od-do
1539-1546
Název nakladatele
Elsevier Ltd
Místo vydání
—
Místo konání akce
Vienna
Datum konání akce
1. 1. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—