Heat and mass transfer measurement using method of digital holographic tomography
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F16%3A00000977" target="_blank" >RIV/46747885:24220/16:00000977 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24210/16:00000977
Výsledek na webu
<a href="http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=2585110&resultClick=1" target="_blank" >http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=2585110&resultClick=1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2257476" target="_blank" >10.1117/12.2257476</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Heat and mass transfer measurement using method of digital holographic tomography
Popis výsledku v původním jazyce
A digital holographic interferometry (DHI) for 3D measurement of temperature distributions in moving fluid is presented in this paper. The measurement uses digital holographic setup for measurement of a flow of fluid propagated through an orifice and tomographic approach for 3D reconstruction of the flow. The periodic character of the flow and synchronization between the digital camera and external trigger driving the phenomenon allows us to measure phenomena with much higher frequency when compared to frame rate of the digital camera. Furthermore one can capture a large number of the flow projections from different viewing directions which are later used for 3D tomographic reconstruction of the whole temperature field of the flow. The measurement results are verified and compared with hot wire method (CTA) in the paper.
Název v anglickém jazyce
Heat and mass transfer measurement using method of digital holographic tomography
Popis výsledku anglicky
A digital holographic interferometry (DHI) for 3D measurement of temperature distributions in moving fluid is presented in this paper. The measurement uses digital holographic setup for measurement of a flow of fluid propagated through an orifice and tomographic approach for 3D reconstruction of the flow. The periodic character of the flow and synchronization between the digital camera and external trigger driving the phenomenon allows us to measure phenomena with much higher frequency when compared to frame rate of the digital camera. Furthermore one can capture a large number of the flow projections from different viewing directions which are later used for 3D tomographic reconstruction of the whole temperature field of the flow. The measurement results are verified and compared with hot wire method (CTA) in the paper.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA16-16596S" target="_blank" >GA16-16596S: Optimalizace generování pulzujících proudů v mechanice tekutin</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of SPIE - The International Society for Optical Engineering
ISBN
9781510607538
ISSN
1996-756X
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
SPIE
Místo vydání
—
Místo konání akce
Liberec
Datum konání akce
1. 1. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—