The MPGD-based photon detectors for the upgrade of COMPASS RICH-1
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F17%3A00005286" target="_blank" >RIV/46747885:24220/17:00005286 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24510/17:00005286 RIV/00216208:11320/17:10369361
Výsledek na webu
<a href="https://api.elsevier.com/content/article/eid/1-s2.0-S0168900217301936" target="_blank" >https://api.elsevier.com/content/article/eid/1-s2.0-S0168900217301936</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2017.02.013" target="_blank" >10.1016/j.nima.2017.02.013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The MPGD-based photon detectors for the upgrade of COMPASS RICH-1
Popis výsledku v původním jazyce
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade for the 2016 physics run. Four new photon detectors, based on Micro Pattern Gaseous Detector technology and covering a total active area larger than 1.2 m 2 have replaced the previously used MWPC-based photon detectors. The upgrade answers the challenging efficiency and stability quest for the new phase of the COMPASS spectrometer physics programme. The new detector architecture consists in a hybrid MPGD combination of two Thick Gas Electron Multipliers and a MicroMegas stage. Signals, extracted from the anode pad by capacitive coupling, are read-out by analog F-E based on the APV25 chip. The main aspects of the COMPASS RICH-1 photon detectors upgrade are presented focussing on detector design, engineering aspects, mass production, the quality assessment and assembly challenges of the MPGD components. The status of the detector commissioning is also presented.
Název v anglickém jazyce
The MPGD-based photon detectors for the upgrade of COMPASS RICH-1
Popis výsledku anglicky
The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade for the 2016 physics run. Four new photon detectors, based on Micro Pattern Gaseous Detector technology and covering a total active area larger than 1.2 m 2 have replaced the previously used MWPC-based photon detectors. The upgrade answers the challenging efficiency and stability quest for the new phase of the COMPASS spectrometer physics programme. The new detector architecture consists in a hybrid MPGD combination of two Thick Gas Electron Multipliers and a MicroMegas stage. Signals, extracted from the anode pad by capacitive coupling, are read-out by analog F-E based on the APV25 chip. The main aspects of the COMPASS RICH-1 photon detectors upgrade are presented focussing on detector design, engineering aspects, mass production, the quality assessment and assembly challenges of the MPGD components. The status of the detector commissioning is also presented.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
ISSN
0168-9002
e-ISSN
—
Svazek periodika
876
Číslo periodika v rámci svazku
02
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
96-100
Kód UT WoS článku
000418267300026
EID výsledku v databázi Scopus
2-s2.0-85011977170