Wide tuned volume coil for small animal MRI on 4.7T
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F18%3A00005500" target="_blank" >RIV/46747885:24220/18:00005500 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24530/18:00005500
Výsledek na webu
<a href="http://www.iupesm2018.org/" target="_blank" >http://www.iupesm2018.org/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Wide tuned volume coil for small animal MRI on 4.7T
Popis výsledku v původním jazyce
Wide tuned radiofrequency volume coil for Small Animal MRI allows receiving of MR signals on wide-band different frequencies. For this reason, it is possible to work with 19F and 1H resonance without changing a special individually coil. The images for different nucleus do not require movement with the animal. Therefore, 1H and 19F images can be easily compared. The birdcage construction of this coil allows volume imaging of small rodents, for example mice. Speciality of this coil is advantageous use of distributed parameters of transmission lines. This solution improves homogeneity of fields, improve resonance quality factor, and allows homogeneous tuning on many points at the same time. The advantage is also the price reduction for elimination of many nonmagnetic lumped capacitors. On 4,7T resonance it works from 185 to 203MHz. Classic Birdcage constructions works only with 3% frequency tuning. A coil produces signal levels comparable with classical one frequency coils. Quality factor unloaded coil is Q200 = 328 a Q188= 331. A Coil was tested on 4,7T Bruker Biospin located at IKEM, Prague.
Název v anglickém jazyce
Wide tuned volume coil for small animal MRI on 4.7T
Popis výsledku anglicky
Wide tuned radiofrequency volume coil for Small Animal MRI allows receiving of MR signals on wide-band different frequencies. For this reason, it is possible to work with 19F and 1H resonance without changing a special individually coil. The images for different nucleus do not require movement with the animal. Therefore, 1H and 19F images can be easily compared. The birdcage construction of this coil allows volume imaging of small rodents, for example mice. Speciality of this coil is advantageous use of distributed parameters of transmission lines. This solution improves homogeneity of fields, improve resonance quality factor, and allows homogeneous tuning on many points at the same time. The advantage is also the price reduction for elimination of many nonmagnetic lumped capacitors. On 4,7T resonance it works from 185 to 203MHz. Classic Birdcage constructions works only with 3% frequency tuning. A coil produces signal levels comparable with classical one frequency coils. Quality factor unloaded coil is Q200 = 328 a Q188= 331. A Coil was tested on 4,7T Bruker Biospin located at IKEM, Prague.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů