Detection of Electromagnetic Interference on Electrodes of Cardiac Implantable Electronic Devices
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F19%3A00006917" target="_blank" >RIV/46747885:24220/19:00006917 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.measurement.sk/M2019/" target="_blank" >http://www.measurement.sk/M2019/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Detection of Electromagnetic Interference on Electrodes of Cardiac Implantable Electronic Devices
Popis výsledku v původním jazyce
The study deals with the interdisciplinary topic of the electromagnetic compatibility of the cardiac implantable electronic devices (CIEDs) that are used in patients with a defect of the heart conduction system. This article points on the issues of electromagnetic interference (EMI) detected on electrodes of cardiostimulation device. The detection of disturbance signals depends on many aspects related to electrode choice, device placement, its configuration and programming. The aim of the study is the analysis of the pacemaker response in the presence of an external source of the disturbance fields. We point to possible risks of its interaction and discuss the mechanisms that can influence the pacemaker sensitivity to EMI. Finally, we present one real case and an experiment of the exposure of the cardiostimulation system to a low-frequency time-varying field. The emphasis of this session is put on physical and technical aspects, but it is also related to the medical part of the issue.
Název v anglickém jazyce
Detection of Electromagnetic Interference on Electrodes of Cardiac Implantable Electronic Devices
Popis výsledku anglicky
The study deals with the interdisciplinary topic of the electromagnetic compatibility of the cardiac implantable electronic devices (CIEDs) that are used in patients with a defect of the heart conduction system. This article points on the issues of electromagnetic interference (EMI) detected on electrodes of cardiostimulation device. The detection of disturbance signals depends on many aspects related to electrode choice, device placement, its configuration and programming. The aim of the study is the analysis of the pacemaker response in the presence of an external source of the disturbance fields. We point to possible risks of its interaction and discuss the mechanisms that can influence the pacemaker sensitivity to EMI. Finally, we present one real case and an experiment of the exposure of the cardiostimulation system to a low-frequency time-varying field. The emphasis of this session is put on physical and technical aspects, but it is also related to the medical part of the issue.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 12th International Conference on Measurement 2019
ISBN
978-809726293-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
182-185
Název nakladatele
Institute of Electrical and Electronics Engineers Inc.
Místo vydání
Bratislava
Místo konání akce
Smolenice, Slovakia
Datum konání akce
1. 1. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—