Inverse modeling of natural tracer transport in a granite massif with lumped-parameter and physically based models: case study of a tunnel in Czechia
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F21%3A00008912" target="_blank" >RIV/46747885:24220/21:00008912 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24620/21:00008912 RIV/60460709:41330/21:88585
Výsledek na webu
<a href="http://link.springer.com/article/10.1007/s10040-021-02389-x" target="_blank" >http://link.springer.com/article/10.1007/s10040-021-02389-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10040-021-02389-x" target="_blank" >10.1007/s10040-021-02389-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Inverse modeling of natural tracer transport in a granite massif with lumped-parameter and physically based models: case study of a tunnel in Czechia
Popis výsledku v původním jazyce
This study deals with numerical modelling of hydraulic and transport phenomena in granite of the Bohemian massif in Bedrichov, Czechia (Czech Republic). Natural tracers represented by stable isotopes δ18O and δ2H were collected at the tunnel outflow points and nearby catchment and their concentrations were monitored for seven years. The study compared transport simulations by a two-dimensional (2D) physically based model (advection-dispersion) developed in Flow123d software and a simpler lumped-parameter model, calculated with FLOWPC. Both variants were calibrated with UCODE software, either fitting the concentration data alone, or including the tunnel inflow rates in the case of the 2D model calibration (either in separate steps or within a single optimization problem). Since each of the models describes the tracer transport with different parameters, the models were compared based on the mean transit time as a postprocessed quantity. Besides this, two different options for processing the recharge data (input for both models) were evaluated. Calibration and data interpretation were possible for three of the four observed places in the tunnel, thus determining the depth limit of applicability of the stable isotopes. The estimates for discharge sampling at 25–35 m depth based on inverse modelling provide reasonable values of mean transit time (20–40 months) for the lumped parameter models, little revising the results of previous studies at the site. The resulting transport parameters of the advection-dispersion model (porosity and dispersivity) are in accordance with the hydrogeological structures present at the sampling sites.
Název v anglickém jazyce
Inverse modeling of natural tracer transport in a granite massif with lumped-parameter and physically based models: case study of a tunnel in Czechia
Popis výsledku anglicky
This study deals with numerical modelling of hydraulic and transport phenomena in granite of the Bohemian massif in Bedrichov, Czechia (Czech Republic). Natural tracers represented by stable isotopes δ18O and δ2H were collected at the tunnel outflow points and nearby catchment and their concentrations were monitored for seven years. The study compared transport simulations by a two-dimensional (2D) physically based model (advection-dispersion) developed in Flow123d software and a simpler lumped-parameter model, calculated with FLOWPC. Both variants were calibrated with UCODE software, either fitting the concentration data alone, or including the tunnel inflow rates in the case of the 2D model calibration (either in separate steps or within a single optimization problem). Since each of the models describes the tracer transport with different parameters, the models were compared based on the mean transit time as a postprocessed quantity. Besides this, two different options for processing the recharge data (input for both models) were evaluated. Calibration and data interpretation were possible for three of the four observed places in the tunnel, thus determining the depth limit of applicability of the stable isotopes. The estimates for discharge sampling at 25–35 m depth based on inverse modelling provide reasonable values of mean transit time (20–40 months) for the lumped parameter models, little revising the results of previous studies at the site. The resulting transport parameters of the advection-dispersion model (porosity and dispersivity) are in accordance with the hydrogeological structures present at the sampling sites.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10500 - Earth and related environmental sciences
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_013%2F0001792" target="_blank" >EF16_013/0001792: Modernizace výzkumné infrastruktury RINGEN</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Hydrogeology Journal
ISSN
1431-2174
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
22
Strana od-do
2633–2654
Kód UT WoS článku
000691229500001
EID výsledku v databázi Scopus
2-s2.0-85113852534