Holter Ecg Monitoring as Method for Assessing Interaction of Implanted Pacemaker And Source of Electromagnetic Interference
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F22%3A00009734" target="_blank" >RIV/46747885:24220/22:00009734 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24530/22:00009734 RIV/27283933:_____/22:00009734
Výsledek na webu
<a href="https://doi.org/10.14311/CTJ.2022.1.04" target="_blank" >https://doi.org/10.14311/CTJ.2022.1.04</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/CTJ.2022.1.04" target="_blank" >10.14311/CTJ.2022.1.04</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Holter Ecg Monitoring as Method for Assessing Interaction of Implanted Pacemaker And Source of Electromagnetic Interference
Popis výsledku v původním jazyce
The aim of the study was to assess the interaction of the cardiostimulation system of the patient and the source of electromagnetic interference (EMI) during the patient’s work by Holter monitoring of ECG. Finally, to analyze ECG recording and evaluate possible pacemaker (PCM) program responses to the presence of EMI. The observation was performed in the selected patient with the single-chamber conventional pacemaker during practicing of a profession in an industrial environment with a real risk of interaction with the defined source of interference. The heart rhythm was monitored with a standard Holter monitor and the measurement was repeated during three work shifts. The PCM was revised before each measurement and at the same time the programming was adjusted for monitoring purposes. The ECG record was back-analyzed and the device response to the presence of EMI was evaluated. No program response to the presence of an interfering electromagnetic field (EMF) was observed from the ECG recording analysis. This program response would manifest to abnormalities in the ECG curve (asynchronous pacing, pacing inhibition, competitive pacing). There were no events in the PCM memory indicating the effect of the EMI.
Název v anglickém jazyce
Holter Ecg Monitoring as Method for Assessing Interaction of Implanted Pacemaker And Source of Electromagnetic Interference
Popis výsledku anglicky
The aim of the study was to assess the interaction of the cardiostimulation system of the patient and the source of electromagnetic interference (EMI) during the patient’s work by Holter monitoring of ECG. Finally, to analyze ECG recording and evaluate possible pacemaker (PCM) program responses to the presence of EMI. The observation was performed in the selected patient with the single-chamber conventional pacemaker during practicing of a profession in an industrial environment with a real risk of interaction with the defined source of interference. The heart rhythm was monitored with a standard Holter monitor and the measurement was repeated during three work shifts. The PCM was revised before each measurement and at the same time the programming was adjusted for monitoring purposes. The ECG record was back-analyzed and the device response to the presence of EMI was evaluated. No program response to the presence of an interfering electromagnetic field (EMF) was observed from the ECG recording analysis. This program response would manifest to abnormalities in the ECG curve (asynchronous pacing, pacing inhibition, competitive pacing). There were no events in the PCM memory indicating the effect of the EMI.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Lekar a technika – Clinician and Technology
ISSN
0301-5491
e-ISSN
—
Svazek periodika
52
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
18-22
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85130040276