Nanosecond compressive fluorescence lifetime microscopy imaging via the RATS method with a direct reconstruction of lifetime maps
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24220%2F23%3A00010758" target="_blank" >RIV/46747885:24220/23:00010758 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389021:_____/23:00583129
Výsledek na webu
<a href="https://opg.optica.org/oe/fulltext.cfm?uri=oe-31-4-5181&id=525632&ibsearch=false" target="_blank" >https://opg.optica.org/oe/fulltext.cfm?uri=oe-31-4-5181&id=525632&ibsearch=false</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1364/OE.474453" target="_blank" >10.1364/OE.474453</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nanosecond compressive fluorescence lifetime microscopy imaging via the RATS method with a direct reconstruction of lifetime maps
Popis výsledku v původním jazyce
The RAndom Temporal Signals (RATS) method has proven to be a useful and versatile method for measuring photoluminescence (PL) dynamics and fluorescence lifetime imaging (FLIM). Here, we present two fundamental development steps in the method. First, we demonstrate that by using random digital laser modulation in RATS, it is possible to implement the measurement of PL dynamics with temporal resolution in units of nanoseconds. Secondly, we propose an alternative approach to evaluating FLIM measurements based on a single-pixel camera experiment. In contrast to the standard evaluation, which requires a lengthy iterative reconstruction of PL maps for each timepoint, here we use a limited set of predetermined PL lifetimes and calculate the amplitude maps corresponding to each lifetime. The alternative approach significantly saves post-processing time and, in addition, in a system with noise present, it shows better stability in terms of the accuracy of the FLIM spectrogram. Besides simulations that confirmed the functionality of the extension, we implemented the new advancements into a microscope optical setup for mapping PL dynamics on the micrometer scale. The presented principles were also verified experimentally by mapping a LuAG:Ce crystal surface.
Název v anglickém jazyce
Nanosecond compressive fluorescence lifetime microscopy imaging via the RATS method with a direct reconstruction of lifetime maps
Popis výsledku anglicky
The RAndom Temporal Signals (RATS) method has proven to be a useful and versatile method for measuring photoluminescence (PL) dynamics and fluorescence lifetime imaging (FLIM). Here, we present two fundamental development steps in the method. First, we demonstrate that by using random digital laser modulation in RATS, it is possible to implement the measurement of PL dynamics with temporal resolution in units of nanoseconds. Secondly, we propose an alternative approach to evaluating FLIM measurements based on a single-pixel camera experiment. In contrast to the standard evaluation, which requires a lengthy iterative reconstruction of PL maps for each timepoint, here we use a limited set of predetermined PL lifetimes and calculate the amplitude maps corresponding to each lifetime. The alternative approach significantly saves post-processing time and, in addition, in a system with noise present, it shows better stability in terms of the accuracy of the FLIM spectrogram. Besides simulations that confirmed the functionality of the extension, we implemented the new advancements into a microscope optical setup for mapping PL dynamics on the micrometer scale. The presented principles were also verified experimentally by mapping a LuAG:Ce crystal surface.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Optics Express
ISSN
1094-4087
e-ISSN
—
Svazek periodika
31
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
19
Strana od-do
5181-5199
Kód UT WoS článku
000942082400004
EID výsledku v databázi Scopus
2-s2.0-85147323918