Combination of nZVI and DC for the in-situ remediation of chlorinated ethenes: An environmental and economic case study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24310%2F20%3A00007646" target="_blank" >RIV/46747885:24310/20:00007646 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24620/20:00007646
Výsledek na webu
<a href="https://doi.org/10.1016/j.chemosphere.2019.125576" target="_blank" >https://doi.org/10.1016/j.chemosphere.2019.125576</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chemosphere.2019.125576" target="_blank" >10.1016/j.chemosphere.2019.125576</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Combination of nZVI and DC for the in-situ remediation of chlorinated ethenes: An environmental and economic case study
Popis výsledku v původním jazyce
Over the past two decades, the use of nanoscale zero-valent iron (nZVI) has emerged as a standard method of contaminated groundwater remediation. The effectiveness of this method depends on key intrinsic hydrogeological parameters, which can affect both reactivity of the nanoparticles and their migration in the aquifer. In the case of low hydraulic permeability, the migration of nanoparticles is limited, which negatively influences remediation. An application of nZVI reinforced with a DC electric field led to a significant increase in the efficiency of remediation, as demonstrated by long-term monitoring at a former industrial site in Horice (Czech Republic). For the method testing, a 12 × 9 m polygon was defined around well IS4, where the original contamination was predominantly composed of DCE (7300 μg/l), and with a total concentration of chlorinated ethenes of 8880 μg/l. During the first stage of the activities, 49 kg of nZVI was injected and monitored for two years. Subsequently, the electrodes were installed, and for three years, the synergistic action of nZVI within an applied DC field was monitored. Based on 32 monitoring campaigns performed over the six years, the combined method was compared with an application of the only nZVI in technical, environmental and economic terms. Technically, the method requires annual reinstallation of anodes as a result of their oxidative disintegration. Environmentally, the method provides significantly improved chlorinated ethane reduction, remediation of low permeable zones, and extended efficiency. Economically, the method is five times cheaper when compared to the nZVI used alone.
Název v anglickém jazyce
Combination of nZVI and DC for the in-situ remediation of chlorinated ethenes: An environmental and economic case study
Popis výsledku anglicky
Over the past two decades, the use of nanoscale zero-valent iron (nZVI) has emerged as a standard method of contaminated groundwater remediation. The effectiveness of this method depends on key intrinsic hydrogeological parameters, which can affect both reactivity of the nanoparticles and their migration in the aquifer. In the case of low hydraulic permeability, the migration of nanoparticles is limited, which negatively influences remediation. An application of nZVI reinforced with a DC electric field led to a significant increase in the efficiency of remediation, as demonstrated by long-term monitoring at a former industrial site in Horice (Czech Republic). For the method testing, a 12 × 9 m polygon was defined around well IS4, where the original contamination was predominantly composed of DCE (7300 μg/l), and with a total concentration of chlorinated ethenes of 8880 μg/l. During the first stage of the activities, 49 kg of nZVI was injected and monitored for two years. Subsequently, the electrodes were installed, and for three years, the synergistic action of nZVI within an applied DC field was monitored. Based on 32 monitoring campaigns performed over the six years, the combined method was compared with an application of the only nZVI in technical, environmental and economic terms. Technically, the method requires annual reinstallation of anodes as a result of their oxidative disintegration. Environmentally, the method provides significantly improved chlorinated ethane reduction, remediation of low permeable zones, and extended efficiency. Economically, the method is five times cheaper when compared to the nZVI used alone.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemosphere
ISSN
0045-6535
e-ISSN
—
Svazek periodika
245
Číslo periodika v rámci svazku
APR
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
000521513100059
EID výsledku v databázi Scopus
2-s2.0-85076374764