New micro-spectrophotometer for measurement of UPF on textile fibre
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F02%3A00000144" target="_blank" >RIV/46747885:24410/02:00000144 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
New micro-spectrophotometer for measurement of UPF on textile fibre
Popis výsledku v původním jazyce
The measurement of Ultraviolet Protection Factor (UPF) of clothing can be performed by measuring the materials defuse transmittance in the ultraviolet (UV). A common textile additive known us an optical brightening agent (OBA or FWA), enhances a fabricsappearance trough optical effect of fluorescent. Ultraviolet spectrophotometer used to measure spectral transmittance can exhibit systematic errors when fluorescent samples are introduced. Common used of spectrophotometers are equipped by deuterium and halogen light sources. This combined spectrum does not relate to daylight, therefore optical response of textile materials with FWA is not adequate. New micro spectrophotometer is optimised to artificial daylight light source, which is approximately eq ualto D65 illumination. This device is adapted to measurement of textile fibres, yarns and fabrics. Our results show that spectral transmittance data of textiles are more reliable than spectral data from classical spectrophotometer. In our
Název v anglickém jazyce
New micro-spectrophotometer for measurement of UPF on textile fibre
Popis výsledku anglicky
The measurement of Ultraviolet Protection Factor (UPF) of clothing can be performed by measuring the materials defuse transmittance in the ultraviolet (UV). A common textile additive known us an optical brightening agent (OBA or FWA), enhances a fabricsappearance trough optical effect of fluorescent. Ultraviolet spectrophotometer used to measure spectral transmittance can exhibit systematic errors when fluorescent samples are introduced. Common used of spectrophotometers are equipped by deuterium and halogen light sources. This combined spectrum does not relate to daylight, therefore optical response of textile materials with FWA is not adequate. New micro spectrophotometer is optimised to artificial daylight light source, which is approximately eq ualto D65 illumination. This device is adapted to measurement of textile fibres, yarns and fabrics. Our results show that spectral transmittance data of textiles are more reliable than spectral data from classical spectrophotometer. In our
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LN00B090" target="_blank" >LN00B090: Výzkumné centrum "Textil"</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
6. Dresdner Textiltagung
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
170
Název nakladatele
TU Dresden
Místo vydání
Dresden, Germany
Místo konání akce
Dresden, Germany
Datum konání akce
19. 6. 2002
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—