Colour Differences for a Farnsworth-Muunsell 100-Hue Test Illuminated by a D65 source
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F11%3A%230001000" target="_blank" >RIV/46747885:24410/11:#0001000 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Colour Differences for a Farnsworth-Muunsell 100-Hue Test Illuminated by a D65 source
Popis výsledku v původním jazyce
From experimental measurements of the 85 samples in a completely new issue of the Farnsworth-Munsell 100-Hue test (D65 source, CIE 1931 colorimetric observer), the next main conclusions were achieved: 1) The 85 samples had almost constant lightness, buthigh chroma variations (coef?cients of variation of L*=3.2% and Cab*=23.7%). 2) On the average, continuous samples showed CIEDE2000 lightness-, chroma- and hue-differences of 26.1%, 12.2% and 61.7%, respectively. 3) Colour differences between contiguoussamples had high coef?cients of variation of 33.9% and 33.5% for the CIEDE2000 and CAMO2-SCD colour-difference formulas respectively. 4) The next anomalous colour-difference pairs were detected: DE(27, 29)< DE(27, 28); DE(35 , 33) < DE(35, 34); DE(47, 49) < DE(47,48); and DE(49 47)< DE(49,48), where DE designates both the CIEDE2000 and CAMO2-SCD colour-difference formulas. 5) Although the reference illuminant for this test was C, the use of illuminant D65 or an appropriate simulator can
Název v anglickém jazyce
Colour Differences for a Farnsworth-Muunsell 100-Hue Test Illuminated by a D65 source
Popis výsledku anglicky
From experimental measurements of the 85 samples in a completely new issue of the Farnsworth-Munsell 100-Hue test (D65 source, CIE 1931 colorimetric observer), the next main conclusions were achieved: 1) The 85 samples had almost constant lightness, buthigh chroma variations (coef?cients of variation of L*=3.2% and Cab*=23.7%). 2) On the average, continuous samples showed CIEDE2000 lightness-, chroma- and hue-differences of 26.1%, 12.2% and 61.7%, respectively. 3) Colour differences between contiguoussamples had high coef?cients of variation of 33.9% and 33.5% for the CIEDE2000 and CAMO2-SCD colour-difference formulas respectively. 4) The next anomalous colour-difference pairs were detected: DE(27, 29)< DE(27, 28); DE(35 , 33) < DE(35, 34); DE(47, 49) < DE(47,48); and DE(49 47)< DE(49,48), where DE designates both the CIEDE2000 and CAMO2-SCD colour-difference formulas. 5) Although the reference illuminant for this test was C, the use of illuminant D65 or an appropriate simulator can
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1M0553" target="_blank" >1M0553: Výzkumné centrum TEXTIL II</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AIC 2011 Midterm Meeting - Interaction of Colours and Light in the Arts and Science - Proceeding
ISBN
978-3-033-02929-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
130-133
Název nakladatele
pro/colore, Swiss
Místo vydání
Zurich, Switzerland
Místo konání akce
Zurich
Datum konání akce
7. 6. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—