A mathematical model of external electrostatic field of a special collector for electrospinning of nanofibers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F14%3A%230003965" target="_blank" >RIV/46747885:24410/14:#0003965 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24510/14:#0001198
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0304388614000102" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0304388614000102</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.elstat.2014.01.003" target="_blank" >10.1016/j.elstat.2014.01.003</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A mathematical model of external electrostatic field of a special collector for electrospinning of nanofibers
Popis výsledku v původním jazyce
This article focuses on the analysis of electrostatic field generated by a special collector consisting of two parallel cylindrical conductors used for electrospinning. Computed values of critical electrical potential obtained by an analytical model arecompared with measurements. Here we show that the gap distance between the special collector and a spinning electrode, i.e., a syringe needle, has not substantial effect on the critical potential if the special collector distance from the syringe needleis higher than the gap distance between cylindrical conductors. The presented model is a good analytical approximation of electric field created by the used special collector. (C) 2014 Elsevier B.V. All rights reserved.
Název v anglickém jazyce
A mathematical model of external electrostatic field of a special collector for electrospinning of nanofibers
Popis výsledku anglicky
This article focuses on the analysis of electrostatic field generated by a special collector consisting of two parallel cylindrical conductors used for electrospinning. Computed values of critical electrical potential obtained by an analytical model arecompared with measurements. Here we show that the gap distance between the special collector and a spinning electrode, i.e., a syringe needle, has not substantial effect on the critical potential if the special collector distance from the syringe needleis higher than the gap distance between cylindrical conductors. The presented model is a good analytical approximation of electric field created by the used special collector. (C) 2014 Elsevier B.V. All rights reserved.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP208%2F12%2F0105" target="_blank" >GAP208/12/0105: ROZTOKY POLYMERŮ VE VNĚJŠÍM POLI: MOLEKULÁRNÍ POCHOPENÍ ELEKTROSPINNINGU</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF ELECTROSTATICS
ISSN
0304-3886
e-ISSN
—
Svazek periodika
72
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
161-165
Kód UT WoS článku
000334482600009
EID výsledku v databázi Scopus
—