Evaluation of Illumination Intensity of Plastic Optical Fibres with Tio2 Particles by Laser Treatment
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F15%3A%230003813" target="_blank" >RIV/46747885:24410/15:#0003813 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.degruyter.com/dg/viewarticle.fullcontentlink:pdfeventlink/$002fj$002faut.2015.15.issue-1$002faut-2014-0016$002faut-2014-0016.pdf?t:ac=j$002faut.2015.15.issue-1$002faut-2014-0016$002faut-2014-0016.xml" target="_blank" >http://www.degruyter.com/dg/viewarticle.fullcontentlink:pdfeventlink/$002fj$002faut.2015.15.issue-1$002faut-2014-0016$002faut-2014-0016.pdf?t:ac=j$002faut.2015.15.issue-1$002faut-2014-0016$002faut-2014-0016.xml</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2478/aut-2014-0016" target="_blank" >10.2478/aut-2014-0016</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of Illumination Intensity of Plastic Optical Fibres with Tio2 Particles by Laser Treatment
Popis výsledku v původním jazyce
CO2 laser treatment can increase the surface roughness of plastic optical fibers (POFs) with the diameter of 0.5 mm and enhance the input intensity and attenuation coefficient accordingly, which is supposed to weaken the side emission of POFs in long distance above 375 mm. TiO2 particles were applied to improve the increasing optical loss of POFs by laser treatment. POFs were first modified with fine TiO2 particles and then treated by CO2 laser with the pixel time from 30 to 120 ?s. The surface morphology was observed by scanning electron microscopy to investigate the changes of micro-structure before and after laser treatment and the distribution of TiO2 particles. The illumination intensity and attenuation coefficient were calculated and compared intwo methods. It is visible that the evaluation by model LLF2 with two parts is more suitable for the fitting of experimental data and shows higher input intensity and lower attenuation than that by standard power function. Both two evalua
Název v anglickém jazyce
Evaluation of Illumination Intensity of Plastic Optical Fibres with Tio2 Particles by Laser Treatment
Popis výsledku anglicky
CO2 laser treatment can increase the surface roughness of plastic optical fibers (POFs) with the diameter of 0.5 mm and enhance the input intensity and attenuation coefficient accordingly, which is supposed to weaken the side emission of POFs in long distance above 375 mm. TiO2 particles were applied to improve the increasing optical loss of POFs by laser treatment. POFs were first modified with fine TiO2 particles and then treated by CO2 laser with the pixel time from 30 to 120 ?s. The surface morphology was observed by scanning electron microscopy to investigate the changes of micro-structure before and after laser treatment and the distribution of TiO2 particles. The illumination intensity and attenuation coefficient were calculated and compared intwo methods. It is visible that the evaluation by model LLF2 with two parts is more suitable for the fitting of experimental data and shows higher input intensity and lower attenuation than that by standard power function. Both two evalua
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Autex Research Journal
ISSN
2300-0929
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
6
Strana od-do
13-18
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—