Improving Electromagnetic Shielding Ability of Plaster-Based Composites by Addition of Carbon Fibers

Identifikátory výsledku

  • Kód výsledku v IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F18%3A00005523" target="_blank" >RIV/46747885:24410/18:00005523 - isvavai.cz</a>

  • Nalezeny alternativní kódy

    RIV/46747885:24620/18:00005523

  • Výsledek na webu

    <a href="https://www.hindawi.com/journals/amse/2018/3758364/" target="_blank" >https://www.hindawi.com/journals/amse/2018/3758364/</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1155/2018/3758364" target="_blank" >10.1155/2018/3758364</a>

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Improving Electromagnetic Shielding Ability of Plaster-Based Composites by Addition of Carbon Fibers

  • Popis výsledku v původním jazyce

    The size of electromagnetic shielding in plaster composites by the means of different volume fractions of carbon fibers was studied in this paper. Conventional types of plaster, which are commonly used in industry, that is, cement, lime, gypsum, and lime cement (Thermo UM), were the base materials of the created composites. The fundamental idea of improving the electromagnetic shielding properties was verified based on a numerical simulation conducted by means of electromagnetic module in Comsol Multiphysics. The carbon microfibers with the above-critical length of 8 mm were added as the reinforcing and simultaneously shielding element into the plaster samples. From the viewpoint of the mechanical properties, fibers shorter than the critical length do not provide sufficient reinforcement. The samples were created at three different volume fractions of the dispersion and one without any reinforcement for the possibilities of their mutual comparison. The results of the carried measurement show that the electromagnetic shielding in the plaster composite grows with the increase of fiber content within the tested ratio proportionately. Also, the dependency of shielding ability on the inner material moisture has been studied. Any measureable influence of the moisture content on to the total shielding effect has not been found. Only in the lime plaster reinforced with fibers, the increased moisture could significantly decrease the shielding effect.

  • Název v anglickém jazyce

    Improving Electromagnetic Shielding Ability of Plaster-Based Composites by Addition of Carbon Fibers

  • Popis výsledku anglicky

    The size of electromagnetic shielding in plaster composites by the means of different volume fractions of carbon fibers was studied in this paper. Conventional types of plaster, which are commonly used in industry, that is, cement, lime, gypsum, and lime cement (Thermo UM), were the base materials of the created composites. The fundamental idea of improving the electromagnetic shielding properties was verified based on a numerical simulation conducted by means of electromagnetic module in Comsol Multiphysics. The carbon microfibers with the above-critical length of 8 mm were added as the reinforcing and simultaneously shielding element into the plaster samples. From the viewpoint of the mechanical properties, fibers shorter than the critical length do not provide sufficient reinforcement. The samples were created at three different volume fractions of the dispersion and one without any reinforcement for the possibilities of their mutual comparison. The results of the carried measurement show that the electromagnetic shielding in the plaster composite grows with the increase of fiber content within the tested ratio proportionately. Also, the dependency of shielding ability on the inner material moisture has been studied. Any measureable influence of the moisture content on to the total shielding effect has not been found. Only in the lime plaster reinforced with fibers, the increased moisture could significantly decrease the shielding effect.

Klasifikace

  • Druh

    J<sub>imp</sub> - Článek v periodiku v databázi Web of Science

  • CEP obor

  • OECD FORD obor

    20505 - Composites (including laminates, reinforced plastics, cermets, combined natural and synthetic fibre fabrics; filled composites)

Návaznosti výsledku

  • Projekt

    <a href="/cs/project/LO1201" target="_blank" >LO1201: ROZVOJ ÚSTAVU PRO NANOMATERIÁLY, POKROČILÉ TECHNOLOGIE A INOVACE TECHNICKÉ UNIVERZITY V LIBERCI</a><br>

  • Návaznosti

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Ostatní

  • Rok uplatnění

    2018

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    Advances in Materials Science and Engineering

  • ISSN

    1687-8434

  • e-ISSN

  • Svazek periodika

    2018

  • Číslo periodika v rámci svazku

    7

  • Stát vydavatele periodika

    GB - Spojené království Velké Británie a Severního Irska

  • Počet stran výsledku

    14

  • Strana od-do

    1-14

  • Kód UT WoS článku

    000440910800001

  • EID výsledku v databázi Scopus

    2-s2.0-85051322399