Enhancement of muscle’s activity by woven compression bandage
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F21%3A00008914" target="_blank" >RIV/46747885:24410/21:00008914 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.revistaindustriatextila.ro/images/2021/4/08" target="_blank" >http://www.revistaindustriatextila.ro/images/2021/4/08</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.35530/IT.072.04.1789" target="_blank" >10.35530/IT.072.04.1789</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Enhancement of muscle’s activity by woven compression bandage
Popis výsledku v původním jazyce
Electromyography the test the recording of electric activity by compression bandages Electromyography (EMG) test, the recording of electrical activity in muscle, is a main tool usually used to evaluate the muscle‘s activation. This study aims to discuss and analyse the effect of woven compression bandage (WCB) on muscles‘ activation. Flexor Carpi (FC), Soleus (SO), and Medial Gastrocnemius (MG) muscles were selected to represent the wrist, ankle, and mid-calf muscles respectively, which were then evaluated by EMG electrical voltage test with and without wearing WCB. The standardized activities used to test the FC muscle were flexion-extension and squeezing a soft roll. While the protocol activities for MG and SO muscles were flexion-extension and walking actions. Wearing WCB significantly decreased the muscle‘s activation and was associated with higher median frequency for both SO and MG muscles during the tested activities. The EMG signals were analysed and filtered using MegaWin and MATLAB software. Root mean square (RMS) values confirmed that wearing WCB could improve the performance of FC, SO, and MG muscles and might reduce the muscle‘s fatigue during the selected activities.
Název v anglickém jazyce
Enhancement of muscle’s activity by woven compression bandage
Popis výsledku anglicky
Electromyography the test the recording of electric activity by compression bandages Electromyography (EMG) test, the recording of electrical activity in muscle, is a main tool usually used to evaluate the muscle‘s activation. This study aims to discuss and analyse the effect of woven compression bandage (WCB) on muscles‘ activation. Flexor Carpi (FC), Soleus (SO), and Medial Gastrocnemius (MG) muscles were selected to represent the wrist, ankle, and mid-calf muscles respectively, which were then evaluated by EMG electrical voltage test with and without wearing WCB. The standardized activities used to test the FC muscle were flexion-extension and squeezing a soft roll. While the protocol activities for MG and SO muscles were flexion-extension and walking actions. Wearing WCB significantly decreased the muscle‘s activation and was associated with higher median frequency for both SO and MG muscles during the tested activities. The EMG signals were analysed and filtered using MegaWin and MATLAB software. Root mean square (RMS) values confirmed that wearing WCB could improve the performance of FC, SO, and MG muscles and might reduce the muscle‘s fatigue during the selected activities.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20503 - Textiles; including synthetic dyes, colours, fibres (nanoscale materials to be 2.10; biomaterials to be 2.9)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Industria Textila
ISSN
1222-5347
e-ISSN
—
Svazek periodika
72
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
RO - Rumunsko
Počet stran výsledku
10
Strana od-do
408-417
Kód UT WoS článku
000694801900008
EID výsledku v databázi Scopus
2-s2.0-85115141388