The wettability of electron spun membranes by synovial fluid
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F21%3A00009200" target="_blank" >RIV/46747885:24410/21:00009200 - isvavai.cz</a>
Výsledek na webu
<a href="https://royalsocietypublishing.org/doi/10.1098/rsos.210892" target="_blank" >https://royalsocietypublishing.org/doi/10.1098/rsos.210892</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1098/rsos.210892" target="_blank" >10.1098/rsos.210892</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The wettability of electron spun membranes by synovial fluid
Popis výsledku v původním jazyce
Aseptic loosening due to periprosthetic osteolysis has been accepted as one of the leading causes of revision procedures in patients with previous joint arthroplasty. Recently, several strategies for suppression of osteolysis were proposed, mostly based on biological treatment such as mitigation of chronic inflammatory reactions. However, these biological treatments do not stop the debris migration but only reduce the inflammatory reaction. To address this shortcoming, we propose the concept of ultrahigh molecular weighted polyethylene particles filtration storage by electrospun membranes. Firstly, the surface tension of synovial fluid (SF) is obtained by use of a pendant droplet. Secondly, the contact angle of the electrospun membranes wetted by two different liquids is measured to obtain the free surface energy using of the Owens–Wendt model. Additionally, the wettability of electrospun membranes by SF as a function of technology parameters is studied.
Název v anglickém jazyce
The wettability of electron spun membranes by synovial fluid
Popis výsledku anglicky
Aseptic loosening due to periprosthetic osteolysis has been accepted as one of the leading causes of revision procedures in patients with previous joint arthroplasty. Recently, several strategies for suppression of osteolysis were proposed, mostly based on biological treatment such as mitigation of chronic inflammatory reactions. However, these biological treatments do not stop the debris migration but only reduce the inflammatory reaction. To address this shortcoming, we propose the concept of ultrahigh molecular weighted polyethylene particles filtration storage by electrospun membranes. Firstly, the surface tension of synovial fluid (SF) is obtained by use of a pendant droplet. Secondly, the contact angle of the electrospun membranes wetted by two different liquids is measured to obtain the free surface energy using of the Owens–Wendt model. Additionally, the wettability of electrospun membranes by SF as a function of technology parameters is studied.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10700 - Other natural sciences
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Royal Society Open Science
ISSN
2054-5703
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
000732548500013
EID výsledku v databázi Scopus
—