DESIGN OF ELECTRICALLY CONDUCTIVE, HIGHLY STRETCHABLE, HYGIENIC ELECTRODES FOR ELECTROTHERAPY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24410%2F25%3A00014695" target="_blank" >RIV/46747885:24410/25:00014695 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.15240/tul/008/2025-1-012" target="_blank" >https://doi.org/10.15240/tul/008/2025-1-012</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DESIGN OF ELECTRICALLY CONDUCTIVE, HIGHLY STRETCHABLE, HYGIENIC ELECTRODES FOR ELECTROTHERAPY
Popis výsledku v původním jazyce
The main objective of this study was to create versatile and wearable electrically conductive electrodes for Transcutaneous Electrical Nerve Stimulation (TENS) application, ensuring they are comfortable by depositing silver particles directly onto the carbon particles imparted rubber electrodes. Scanning Electron Microscopy (SEM) was used to analyze the shape of the deposited silver particles. To enhance the electrode‘s performance during body movements, the conductive fabrics were stretched repeatedly, and changes in resistivity were observed. The electrical resistance showed minimal variation with small extensions, remaining relatively constant between 0–75% stretch. Resistance increased significantly after 80% stretch, but the fabric‘s resistivity remained stable even after over 100 stretching cycles. Additionally, there was no significant change in resistivity over time at a constant current. The study also investigated the antibacterial properties of the deposited particles against bacteria like Staphylococcus aureus and Escherichia coli. The antifungal activity assessment using Aspergillus fumigatus further underscores the benefits of the silver-plated elastomers in combating fungal growth. Finally, the durability of the coated fabrics concerning comfort and electrical properties was evaluated through multiple pressure applied, showing good particle retention and only a slight decrease in conductivity.
Název v anglickém jazyce
DESIGN OF ELECTRICALLY CONDUCTIVE, HIGHLY STRETCHABLE, HYGIENIC ELECTRODES FOR ELECTROTHERAPY
Popis výsledku anglicky
The main objective of this study was to create versatile and wearable electrically conductive electrodes for Transcutaneous Electrical Nerve Stimulation (TENS) application, ensuring they are comfortable by depositing silver particles directly onto the carbon particles imparted rubber electrodes. Scanning Electron Microscopy (SEM) was used to analyze the shape of the deposited silver particles. To enhance the electrode‘s performance during body movements, the conductive fabrics were stretched repeatedly, and changes in resistivity were observed. The electrical resistance showed minimal variation with small extensions, remaining relatively constant between 0–75% stretch. Resistance increased significantly after 80% stretch, but the fabric‘s resistivity remained stable even after over 100 stretching cycles. Additionally, there was no significant change in resistivity over time at a constant current. The study also investigated the antibacterial properties of the deposited particles against bacteria like Staphylococcus aureus and Escherichia coli. The antifungal activity assessment using Aspergillus fumigatus further underscores the benefits of the silver-plated elastomers in combating fungal growth. Finally, the durability of the coated fabrics concerning comfort and electrical properties was evaluated through multiple pressure applied, showing good particle retention and only a slight decrease in conductivity.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20503 - Textiles; including synthetic dyes, colours, fibres (nanoscale materials to be 2.10; biomaterials to be 2.9)
Návaznosti výsledku
Projekt
<a href="/cs/project/GM21-32510M" target="_blank" >GM21-32510M: Pokročilé struktury pro tepelnou izolaci v extrémních podmínkách</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů