Optimization of the plunger cooling by the core with high thermal conductivity
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24510%2F19%3A00005790" target="_blank" >RIV/46747885:24510/19:00005790 - isvavai.cz</a>
Výsledek na webu
<a href="https://aip.scitation.org/doi/abs/10.1063/1.5133556" target="_blank" >https://aip.scitation.org/doi/abs/10.1063/1.5133556</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5133556" target="_blank" >10.1063/1.5133556</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optimization of the plunger cooling by the core with high thermal conductivity
Popis výsledku v původním jazyce
The contribution deals with formulation of the optimization problem for the plunger which is cooled by the metal core with high thermal conductivity in combination with the insulation barrier with low thermal conductivity. The thermal energy is removed from the core to the water cooler and converted into steam there. Shape optimization of the core and the insulation barrier is carried out with the aim of achieving the prescribed constant temperature on the outer surface of the plunger at the time of separation of the plunger and the glass piece. The cost functional is the squared L^2_r norm of the difference between the prescribed constant and the temperature on the outward boundary of the plunger at time of separation. The existence and uniqueness of the solution to the state problem and the existence of a solution to the shape optimization problem are introduced.
Název v anglickém jazyce
Optimization of the plunger cooling by the core with high thermal conductivity
Popis výsledku anglicky
The contribution deals with formulation of the optimization problem for the plunger which is cooled by the metal core with high thermal conductivity in combination with the insulation barrier with low thermal conductivity. The thermal energy is removed from the core to the water cooler and converted into steam there. Shape optimization of the core and the insulation barrier is carried out with the aim of achieving the prescribed constant temperature on the outer surface of the plunger at the time of separation of the plunger and the glass piece. The cost functional is the squared L^2_r norm of the difference between the prescribed constant and the temperature on the outward boundary of the plunger at time of separation. The existence and uniqueness of the solution to the state problem and the existence of a solution to the shape optimization problem are introduced.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10102 - Applied mathematics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AIP Conference Proceedings, 2172, art. no. 070020
ISBN
978-0-7354-1919-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
—
Místo vydání
—
Místo konání akce
Sozopol
Datum konání akce
1. 1. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—