Voltammetric Determination of Aclonifen at a Silver Amalgam Electrode in Drinking and River Water
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24620%2F17%3A00004354" target="_blank" >RIV/46747885:24620/17:00004354 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/17:10367367
Výsledek na webu
<a href="https://www.degruyter.com/downloadpdf/j/eces.2017.24.issue-2/eces-2017-0019/eces-2017-0019.pdf" target="_blank" >https://www.degruyter.com/downloadpdf/j/eces.2017.24.issue-2/eces-2017-0019/eces-2017-0019.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/eces-2017-0019" target="_blank" >10.1515/eces-2017-0019</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Determination of Aclonifen at a Silver Amalgam Electrode in Drinking and River Water
Popis výsledku v původním jazyce
A method for the determination of pesticide Aclonifen (AC) in drinking and river water by differential pulse voltammetry (DPV) on a meniscus modified silver solid amalgam electrode (m-AgSAE) using solid phase extraction (SPE) as a cleanup and preconcentration procedure is described. The limit of detection (LOD) for direct DPV determination of AC in deionized water is 2.7·10-8 mol·dm-3. LOD for DPV determination of AC in tap water after SPE is 1.6·10-10 mol·dm-3, the recovery being 55%. LOD for the determination of AC in Vltava river water is 1.9·10-9 mol·dm-3, the recovery being 65%. Humic acids interfere with the determination in river water; this problem can be resolved by adjusting the pH of the extracted sample to 6. The advantages of this approach are high sensitivity, low LOD, quick and easy sample preparation and fast determination.
Název v anglickém jazyce
Voltammetric Determination of Aclonifen at a Silver Amalgam Electrode in Drinking and River Water
Popis výsledku anglicky
A method for the determination of pesticide Aclonifen (AC) in drinking and river water by differential pulse voltammetry (DPV) on a meniscus modified silver solid amalgam electrode (m-AgSAE) using solid phase extraction (SPE) as a cleanup and preconcentration procedure is described. The limit of detection (LOD) for direct DPV determination of AC in deionized water is 2.7·10-8 mol·dm-3. LOD for DPV determination of AC in tap water after SPE is 1.6·10-10 mol·dm-3, the recovery being 55%. LOD for the determination of AC in Vltava river water is 1.9·10-9 mol·dm-3, the recovery being 65%. Humic acids interfere with the determination in river water; this problem can be resolved by adjusting the pH of the extracted sample to 6. The advantages of this approach are high sensitivity, low LOD, quick and easy sample preparation and fast determination.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ecological Chemistry and Engineering S
ISSN
1898-6196
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
8
Strana od-do
277-284
Kód UT WoS článku
000410753700008
EID výsledku v databázi Scopus
—