Droplets size evolution of dispersion in a stirred tank
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24620%2F18%3A00005850" target="_blank" >RIV/46747885:24620/18:00005850 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985874:_____/18:00482057 RIV/68407700:21220/18:00321908
Výsledek na webu
<a href="https://www.epj-conferences.org/articles/epjconf/pdf/2018/15/epjconf_efm2018_02053.pdf" target="_blank" >https://www.epj-conferences.org/articles/epjconf/pdf/2018/15/epjconf_efm2018_02053.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epiconf/201818002053" target="_blank" >10.1051/epiconf/201818002053</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Droplets size evolution of dispersion in a stirred tank
Popis výsledku v původním jazyce
Dispersion of two immiscible liquids is commonly used in chemical industry as wall as in metallurgical industry e.g. extraction process. The governing property is droplet size distribution. The droplet sizes are given by the physical properties of both liquids and flow properties inside a stirred tank. The first investigation stage is focused on in-situ droplet size measurement using image analysis and optimizing of the evaluation method to achieve maximal result reproducibility. The obtained experimental results are compared with multi-phase flow simulation based on Euler-Euler approach combined with PBM (Population Balance Modelling). The population balance model was, in that specific case, simplified with assumption of pure breakage of droplets.
Název v anglickém jazyce
Droplets size evolution of dispersion in a stirred tank
Popis výsledku anglicky
Dispersion of two immiscible liquids is commonly used in chemical industry as wall as in metallurgical industry e.g. extraction process. The governing property is droplet size distribution. The droplet sizes are given by the physical properties of both liquids and flow properties inside a stirred tank. The first investigation stage is focused on in-situ droplet size measurement using image analysis and optimizing of the evaluation method to achieve maximal result reproducibility. The obtained experimental results are compared with multi-phase flow simulation based on Euler-Euler approach combined with PBM (Population Balance Modelling). The population balance model was, in that specific case, simplified with assumption of pure breakage of droplets.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences. Volume 180, 2018 EFM17 – Experimental Fluid Mechanics 2017
ISBN
—
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
EPJ Web of Conferences
Místo vydání
CEDEX A, FRANCE
Místo konání akce
Mikulov; Czech Republic
Datum konání akce
1. 1. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000454317800054