Effect of Particle Image Velocimetry Setting Parameters on Local Velocity Measurements in an Agitated Vessel
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24620%2F19%3A00006988" target="_blank" >RIV/46747885:24620/19:00006988 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985874:_____/19:00501006 RIV/68407700:21220/19:00331150
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/full/10.1002/ceat.201800589" target="_blank" >https://onlinelibrary.wiley.com/doi/full/10.1002/ceat.201800589</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/ceat.201800589" target="_blank" >10.1002/ceat.201800589</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of Particle Image Velocimetry Setting Parameters on Local Velocity Measurements in an Agitated Vessel
Popis výsledku v původním jazyce
Although they are obtained under the same conditions, results on the flow field in an agitated vessel achieved using particle image velocimetry (PIV) may vary due to differences in the PIV conditions. The influence on turbulence characteristics of the main PIV setting parameters, i.e., PIV spatial resolution, sampling frequency, and recording time, was investigated. Tests were performed with three different liquids in a developed turbulent field for a Rushton turbine impeller using two-dimensional time-resolved PIV. To obtain the relevant velocity gradients, a minimum recording time is needed. No effect of sampling frequency was observed if the sampling frequency was higher than approximately 17 times the impeller frequency, which is about three times the impeller blade frequency.
Název v anglickém jazyce
Effect of Particle Image Velocimetry Setting Parameters on Local Velocity Measurements in an Agitated Vessel
Popis výsledku anglicky
Although they are obtained under the same conditions, results on the flow field in an agitated vessel achieved using particle image velocimetry (PIV) may vary due to differences in the PIV conditions. The influence on turbulence characteristics of the main PIV setting parameters, i.e., PIV spatial resolution, sampling frequency, and recording time, was investigated. Tests were performed with three different liquids in a developed turbulent field for a Rushton turbine impeller using two-dimensional time-resolved PIV. To obtain the relevant velocity gradients, a minimum recording time is needed. No effect of sampling frequency was observed if the sampling frequency was higher than approximately 17 times the impeller frequency, which is about three times the impeller blade frequency.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
CHEMICAL ENGINEERING & TECHNOLOGY
ISSN
0930-7516
e-ISSN
—
Svazek periodika
42
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
827-834
Kód UT WoS článku
000462235100016
EID výsledku v databázi Scopus
2-s2.0-85061918657