Comparative investigation of acetaminophen degradation in aqueous solution by UV/Chlorine and UV/H2O2 processes: Kinetics and toxicity assessment, process feasibility and products identification
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24620%2F21%3A00008879" target="_blank" >RIV/46747885:24620/21:00008879 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0045653521019275" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0045653521019275</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chemosphere.2021.131455" target="_blank" >10.1016/j.chemosphere.2021.131455</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparative investigation of acetaminophen degradation in aqueous solution by UV/Chlorine and UV/H2O2 processes: Kinetics and toxicity assessment, process feasibility and products identification
Popis výsledku v původním jazyce
The degradation of acetaminophen (ACM) was comparatively studied by UV/chlorine and UV/H2O2 systems. An apparent reduction in the removal rate was observed above the optimum pH levels of 7.0 and 3.0 in UV/chlorine and UV/H2O2 processes, respectively. The relative contribution of each oxidizing agent in ACM removal using the two advanced oxidation processes (AOPs) was evaluated. Even though hydroxyl radicals, with the contribution percentage of 90.1%, were determined as the primary oxidizing species in ACM removal using the UV/H2O2 process, reactive chlorine species (RCS), with 43.8% of contribution percentage, were also found to play a pivotal role in ACM removal using the UV/chlorine process. For instance, dichlorine radical (Cl2•-) showed an acceptable contribution percentage of 32.2% in the degradation of ACM by the UV/chlorine process. The rate of ACM degradation significantly rose to 99.9% and 75.6%, as higher amounts of oxidants were used in the UV/chlorine and UV/H2O2 processes, respectively, within 25 min. The introduction of HCO3− ions and humic acid remarkably decreased the rate of ACM degradation in both techniques used in this study. The presence of NO3− and Cl− ions did not considerably affect the removal rate in the UV/chlorine process. The acute toxicity analysis revealed that a more pronounced reduction in the ACM solution toxicity could be achieved by the UV/H2O2 process compared to the UV/chlorine process, which should be ascribed to the formation of chlorinated products in the UV/chlorine treatment. Eventually, plausible oxidation pathways were proposed for each process.
Název v anglickém jazyce
Comparative investigation of acetaminophen degradation in aqueous solution by UV/Chlorine and UV/H2O2 processes: Kinetics and toxicity assessment, process feasibility and products identification
Popis výsledku anglicky
The degradation of acetaminophen (ACM) was comparatively studied by UV/chlorine and UV/H2O2 systems. An apparent reduction in the removal rate was observed above the optimum pH levels of 7.0 and 3.0 in UV/chlorine and UV/H2O2 processes, respectively. The relative contribution of each oxidizing agent in ACM removal using the two advanced oxidation processes (AOPs) was evaluated. Even though hydroxyl radicals, with the contribution percentage of 90.1%, were determined as the primary oxidizing species in ACM removal using the UV/H2O2 process, reactive chlorine species (RCS), with 43.8% of contribution percentage, were also found to play a pivotal role in ACM removal using the UV/chlorine process. For instance, dichlorine radical (Cl2•-) showed an acceptable contribution percentage of 32.2% in the degradation of ACM by the UV/chlorine process. The rate of ACM degradation significantly rose to 99.9% and 75.6%, as higher amounts of oxidants were used in the UV/chlorine and UV/H2O2 processes, respectively, within 25 min. The introduction of HCO3− ions and humic acid remarkably decreased the rate of ACM degradation in both techniques used in this study. The presence of NO3− and Cl− ions did not considerably affect the removal rate in the UV/chlorine process. The acute toxicity analysis revealed that a more pronounced reduction in the ACM solution toxicity could be achieved by the UV/H2O2 process compared to the UV/chlorine process, which should be ascribed to the formation of chlorinated products in the UV/chlorine treatment. Eventually, plausible oxidation pathways were proposed for each process.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemosphere
ISSN
0045-6535
e-ISSN
—
Svazek periodika
285
Číslo periodika v rámci svazku
December
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
000703680800001
EID výsledku v databázi Scopus
2-s2.0-85110191503